2221315 Inverter

Summary of Contents for 2221315

Page 1: ...2221315 Inverter ...

Page 2: ...ubstandard wiring Make sure that all wiring is in good condition and is not undersized ELECTRICAL SHOCK HAZARD FIRE AND BURN HAZARD EXPLOSION HAZARD Failure to follow these instructions will result in death or serious injury Do not cover or obstruct the air intake vent openings and or install in a zero clearance compartment Do not use transformer less battery chargers in conjunction with the inver...

Page 3: ... protects the battery from being completely discharged HIGH BATTERY VOLTAGE SHUTDOWN Shuts the inverter down automatically if the input voltage rises to 31 volts or more OVER LOAD SHUTDOWN Shuts the inverter down automatically if the loads connected to the inverter exceed the inverter s operating limits OVER TEMPERATURE SHUTDOWN Shuts the inverter down automatically if its internal Temperature ris...

Page 4: ... indicates the inverter is operating 7 AC OUTLETS are used to power loads 8 USB port it output DC5V 2 1A for charge for your appliance 9 ON OFF SWITCH turns the Inverter on and off 10 Remote ON OFF connector port is used for connecting the ON OFF remote switch 5 2 POWER SYSTEM CONNECTION EXAMPLE Figure 4 Typical power system designs 5 3 BATTERY REQUIREMENTS Battery type and battery size strongly a...

Page 5: ...rs on the positive cable line in your power system following these recommendations when you purchasing fuses or circuit breakers Select a fuse or circuit breaker with a maximum rating of 150Adc Determine the short circuit current rating of the battery and choose a battery fuses that withstand the short circuit current that may be generated by the battery 9 INSTALL THE INVERTER Review and follow th...

Page 6: ...e negative DC input terminal on the inverter 6 Attach the other end of the negative DC input cable to the negative terminal of the battery If you have installed a battery selector switch set it to off when making the connection to prevent sparking NOTE This is last cable connection A spark is normal when you make the connection to This section explains how to operate the inverter efficiently and e...

Page 7: ...Some induction motors used in freezers pumps and other motor operated equipment require high surge currents to start The inverter may not be able to start some of these motors even though their rated current draw is within the inverter s limits The inverter will normally start single phase induction motors Some equipment may be not work well or damaged by the inverter s modified sine wave output S...

Page 8: ...na provides an adequate snow free signal and that you are using good quality cable between the antenna and the television 3 Keep the cables between the battery and the inverter as short as possible and twist them together with two to three twists per foot this minimizes radiated interference from the cables Move the television as far away from the inverter as possible Do not operate high power loa...

Page 9: ...ed by damage may adversely affect human health and harm the environment during recycling WARRANTY CARD 19 WARRANTY AND SERVICE AGREEMENTS This warranty covers only manufacturing defects The appliance must not be modified or altered in any way with regards to both form and function This warranty does not apply in case of improper usage usage that falls beyond normal use as indicated in the user s m...