Technical data
28
· G&D ControlCenter-Digital-288
Technical data
CONTROLCENTER-DIGITAL-288
Interfaces
IO slots:
18 × slots to plug in an IO card
Network connection:
2 × RJ45 socket
Direct connection to another
matrix switch:
2 × RJ45 socket
reserved for future functions
RS 232:
1 × RJ11/12 socket
reserved for future functions
USB
2 × USB-A socket
reserved for future functions
DisplayPort
1 × DisplayPort socket
reserved for future functions
Power supply
Amount:
Max. 3
Type:
Internal power supply module
Connection:
1 × IEC plug (IEC-320 C14)
Current consumption:
100-240VAC/60-50Hz, 8-4A
Housing
Material:
Anodised aluminium
Dimensions (W × H × D):
19” × 9U × 500 mm
Weight:
Approx. 31 to40 kg
depending on number and types of IO cards
Operational
environment
Temperature:
+5 to +40 °C
Air humidity:
20 % to 80 %, non-condensing
Storage
environment
Temperature:
-20 °C to +60 °C
Air humidity:
15 % to 85 %, non-condensing
Conformity
CE, RoHS