12
.............................
CCEC/ OM Manual GlasStile GSS 1.6 EN
07
.2009
Operating Modes
Instant Start
This is similar to Push to Go, with the difference that the gate starts immediately when it receives an
impulse. If a pre-rotation acknowledgement has been selected, it is possible to stack up to 5
authorisations per direction. If passage is authorised in both directions, the queue in the first direction
selected is cleared before the gate begins to rotate in the other direction.
Push to Go
A signal applied at one of the impulse unit inputs releases the brake, switches the gate closed output.
Passage can now occur within the selected time. If no passage is started within this time, the gate is
locked and a new impulse must be given. The gate starts to rotate in the selected direction once the
panel is released from its home position. When the gate starts, the acknowledgement relay is
activated for 0.5 seconds.
Depending upon the program set up, an acknowledgement of 0.5 seconds is given when the opening
is completed. The gate closed output is then activated.
Reset
After repeated incorrect use or blocking of the unit, the GlasStile GSS will go into alarm mode, with an
optional remote alarm indication being set in the reception area. There are three ways to reset the unit
to normal operation:
New impulse from pulse transmitter
Reset from (option) reception push buttons via depressing both buttons simultaneously.
If these resets do not happen within 10 seconds after alarm, the GlasStile GSS will
automatically reset itself and return to the home position.
Remote Push Button Activation (Optional)
A reset button in the reception area is connected via diodes to both Left and Right entry reception
inputs. The external diode to reception is connected to the closed gate input on the PCB.
Safety
When the gate is locked, the electro-mechanical brake is activated on full power for 0.5 seconds the
power is then reduced to a steady rate. This is to reduce the risk of heat build up in the brake.
Blocking the GlasStile GSS
If the GlasStile GSS is blocked completely during operation for more than 10 seconds the unit will go
into alarm mode and will reset via the receipt of a valid reset, passage authorisation or time out signal.
Power Failure
In the event of power failure the gate rotates freely. When the power returns the gate searches first for
its internal zero position and then for the home position similar to when the gate is started up.
Fire Alarm
There is a facility for an external fire alarm input contact in the gate. The fire alarm N/C contact is
connected so that it will interrupt the power to the gate. The unit will freewheel until the contact is
remade.