11
.............................
CCEC/ OM Manual GlasStile GSR 1.6 EN
07
.2009
Section 3
Instructions for Use
Instructions for Use
Starting the GlasStile
When power is switched on, the unit automatically searches for its internal zero position, moving
at a lower speed than normal. Once it has reached the blocking panel, it then automatically
moves to its programmed home position. The first time the gate is powered up it will move to its
default home position.
When the internal zero and home positions are being sought, the alarm output flashes slowly.
When searching has been completed the brake engages and the gate closed output switches.
Reception Control Pass Left / Pass Right
There are two reception inputs, one each for
PASS LEFT
and
PASS RIGHT
directions.
The GlasStile GSR is passable for as long as the contact remains closed. On contact opening
the gate returns to its home position, where the electro-mechanical brake locks the wing back in
the barrier position.
No intrinsic acknowledgement of the rotation is given. The closed gate lamp illuminates and the
Status lights change from green to red.