background image

DIGITAL LEVEL

(GT1004)

User’s Manual

DESCRIPTION

This digital level is a highly versatile leveling tool 
designed for fast, easy operation by carpenters, 
stonemasons, bricklayers, other building trades 
workers, surveyors, millwrights and other 
metalworkers, and in some photographic or video 
work, particularly in civil engineering applications, 
such as building construction and steel structure 
erection, for on-site angle alignment and leveling.

Technical Data

Measuring range of digital display: 4×90°

Resolution of Digital Display: ±0.05°

Precision of Digital Display : ±0.1° at 0° & 
90°; ±0.2°at other angles.

Unit of measurement °degrees, % percent, 
mm/m & IN/FT - (in 1/8”/feet increments)

Selectable audible indicator

Hold function

0°calibration

“V” base to help measure round surfaces

Magnetic base

Battery type : 2x1.5V LR03 AAA batteries

Working temperature: 0°C – 40°C

Storage temperature: -10°C - 50°C

Dimensions: 254x27x59mm

Weight: 367g

OPERATION INSTRUCTIONS

1. Battery replacement

Remove the 4 screws to open the battery 
compartment cover.

Insert the two LR03 AAA batteries, observing the 
correct polarity as indicated in the compartment, 
then screw the cover back in place, taking care that 
the rubber seal is in contact with the cover.

2.

 

Powering ON/OFF

Press the “     ” button to turn on the device.
Press the button again to turn off the device.
(After about 3 minutes of non use the device
powers off automatically.)

3. Measuring

Turn on the device and place it with the “V” grooved 
base on the surface to be measured.

This way

Not this way

4.

 

Mode Selection

Pressing the “MODE” button changes the display 
modes from degrees (°) to percent (%), to 
(mm/m), to pitch (IN/FT). The “              ” shows 
the current angle’s position, relative to the 
horizontal or vertical position.

5. Relative or absolute angle measurement

The “Ref” button will set the current angle to zero 
thus allowing measurement of angles relative to 
that angle. Pressing the button again returns to 
the “Absolute” measurement mode.

6. Audible buzzer

Pressing the “      “ button for a short time enables
an audible indication when the device is either 
exactly horizontal or vertical.

7. The Hold function

Pressing the “

HOLD

” button with save the current

angle on the display until the button is pressed 
again or the device is turned off.

8. Low battery indicator

Replace the two AAA cells when the “    “ shows 
on the screen.

9. User calibration

The device is calibrated in the factory but may be
recalibrated by the user if felt necessary.

1. With the device turned OFF, press and 

hold the “

CAL

” and then press the “     “ 

button, release when the display shows 

CAL”;

2. a) Place the device on a flat and clean

surface, press the “

CAL

” button once

and the screen should show “

CAL1

”;

b)  Rotate the device (180°) parallel to the
surface in the same location, then press 
the “

CAL

” button again, the display will 

show “

CAL2

”.

3. Turn off the device which is now 

calibrated.

Reviews: