12
©
Guldmann
G
B
/U
S
-1
19
7/
03
/0
7
•
#
94
41
26
©
Guldmann
G
B
/U
S
-1
19
7/
03
/0
7
•
#
94
41
26
©
Guldmann
G
B
/U
S
-1
19
7/
03
/0
7
•
#
94
41
26
Description of mechanical emergency lowering
– lifting platform
The emergency lowering must be used in
emergencies only. The emergency lowering
must be reset after use. This requires
qualified assistance.
You must contact the dealer before
using the LP5 & the LP5+ again.
Great attention and the
required mobility is needed
to use the emergency
lowering, which is why
the person responsible
for the use of the lifting
platform should be
called.
The person responsible
must have read the
manual so that he can be
called at any time to assist a user.
The platform is lowered by carefully turning the Allen screw that is located in
the floor of the lifting platform until the platform begins to descend.
Description of emergency
lowering – access ramp
The access ramp is fitted with a bolt
in the actuator. Unscrew this bolt
and the access ramp opens up.
Important!
When the bolt has been removed
from the access ramp, the access
ramp is no longer attached – hold
the access ramp firmly when
removing the bolts.
Safety curtain
Ensures that nobody can move in beneath the
platform when it is at its highest level and thereby
risk getting caught when the lifting platform is
lowered. The safety curtain is fitted upon delivery.