EPM Alarms
Alarm
Signification
Corrective actions
CO
Amber
Carbon
monoxide
cabin
pollution
1. Shut cabin heater OFF
2. Open vents
3. Ground or hover : change heading
4. If symptoms of CO poisoning (headache,
drowsiness, dizziness) accompany light,
LAND IMMEDIATELY
MGB / TGB
Chips
Amber
Gearbox
degradation
If alarm is accompanied by any indication of
a problem such as noise, vibration or MGB
temperature light,
LAND IMMEDIATELY
If there is no other indication of a problem,
LAND AS SOON AS POSSIBLE
Fire
Red
Engine
compartment
fire
Refer to procedure page 3-6
LAND IMMEDIATELY
Parameter
Exceeds
Corrective actions
LOW FUEL
Display in
Red
10 L
(2.6 U.S. gal)
Check with LOW FUEL warning light
If ON :
LAND IMMEDIATELY
BATT
Battery
charge
Yellow
Check ALT switch ON.
Battery is not being charged. Turn all non-
essential equipment OFF.
LAND AS SOON AS POSSIBLE
Caution
: Prolonged flight without alternator
can result in loss of electronic and electrical
equipments.