Hélicoptères Guimbal
SECTION 2
CABRI G2
LIMITATIONS
2-12
Sensors failures
When the MASTER is switched on, the EPM carries out a self-test and
displays a test page (refer to page 7-13).
Only one flight should be performed after one of following parameters
are displayed “
Failed
”, with following restrictions :
Failed parameter
Flight restriction
OAT
Use Section 5 to compute available performance
Apply a margin on temperature
Pressure
Limit MLI to 85% in PWR mode, 95% for 5 minutes
or 100% in FLO mode
T. induction
Carb. heat test : control through NR drop
CHT
Avoid long hover.
Carb. T
Control carb. heat manually
Use carb. heat below 80% MLI
ManP
Use Section 5 to compute available performance
Throttle
Use Section 5 to compute available performance
Oil T
Avoid prolonged hover. Monitor CHT
Oil P
Monitor CLUTCH and OIL P. lights
Fuel Q
Perform an accurate fuel planning
MGB/TGB Chips
Hand-check corresponding plug at take-off
Battery charge
Minimize electrical loads
CO
Keep cabin heat closed
Carb. heat control
Control carb. heat manually
Use carb. heat below 80% MLI