Hélicoptères Guimbal
SECTION 7
CABRI G2
SYSTEMS DESCRIPTIONS
7-14
Approved under DOA EASA.21J.211
Start indicator
In START mode, MLI indicates the throttle position
(blue arrow) to assist the pilot to start the engine.
Mode deactivation
when NR ≥ 420 RPM
Mode reactivation when NR
≤
300 RPM
Clock - Stopwatch - Flight time counter
The clock is a continuous display. 12 or 24 - hour format can be selected
through configuration page.
The technical flight time counter is counting the time spent from
NR ≥ 450 RPM
, and until NR
≤
400 RPM.
It discounts the warming, cooling and briefing times in a flight.
Its display is frozen when NR drops below 400 RPM, and is reset zero
only on the next flight, when NR increases above 100 RPM.
The flight time is counted when rotor is turning (from and until NR =
100 RPM). It is not displayed on main page.
At the end of a flight, technical and flight times are recorded in the flight
log pages (refer to page 7-12). Average fuel flow logged is counted with
respect to flight time.
The stopwatch can be activated and started instantly by pressing the #1
key once. It then replaces the flight time display.
The flight time display comes back after 20 s of stopwatch being inactive
at zero, or by pressing #2 key from stopped state.