Standard Sensor Connections - Direct
19
To Connect a Cable to the RadaScan
Sensor:
1. Unscrew the M4 socket screws around the
inspection hatch and remove the inspection
hatch from the front of the sensor.
2. Remove the screw head from a watertight
cable gland on the inspection hatch.
3. Feed the cable through the screw head and
gland.
4. Connect the cable to the correct socket/
terminal inside the sensor.
5. When all connections have been made,
apply DC4 compound around the seal of
the inspection hatch and replace the hatch.
Tighten all of the cable glands to ensure a
watertight seal.
Inspection
Hatch
Cable
Glands
Radome
E
E
N
N
L
L
SCR
TX-
TX+
GND
RS422 Link
9600 baud
8 bits
1 stop bit
No parity
†
See
Changing
the Sensor
IP Address
Setting
page 34
or contact
Guidance
Marine if
alternative
settings are
required.
Ethernet
Link to
RadaScan
Type 2
Marine
Processor
RS422 Link
to Vessel’s
DP System
Mains Power
115VAC 45-65Hz 2.8A
240VAC 45-65Hz 1.2A
CAT 5e
Cable
Internal
Ethernet
Cable
Default IP Addresses:
†
RadaScan Sensor:
192.168.2.231
Subnet Mask:
255.255.255.0
Type 2 Marine Processor (LAN1):
192.168.2.241
Subnet Mask:
255.255.255.0
Heater Power
115VAC 45-65Hz 42A
240VAC 45-65Hz 27A