Digit display
The digit display serves for communication.
LED
The LED indicates the function:
• The green and red LEDs glow for 5 seconds after activation to check their
own status
• The green LED glows during the lubrication cycle
• The green LED flashes if there is no error
• The red LED flashes every 5 seconds if there is an error
Fault message
The fault message shows the type of error. More detailed information
4.2.2.4
Control elements
The magnetic peg is magnetic and integrated into the vent locking mechanism.
Remove the vent locking mechanism to use the magnetic peg. Touch the ac-
tive surface with it to perform the following actions:
• Switch the FlexxPump on and off
• Set lubrication cycle
• Perform functional check
D003499
A
C
B
Fig. 4-5
Magnetic peg
A
Vent locking mechanism
B
Active surface
C
Magnetic peg
Design, function
OPERATING MANUAL Automatic lubrication system
FlexxPump 402 / 402B
90071992656444683_v9.0_
EN-US
40