3.3.2.3
Minimum lubrication quantity
Splitters only function correctly if > 0.5 cm
3
of lubricant is produced at their
input per lubrication cycle.
3.3.2.4
Maximum pressure
The maximum pressure at the input of splitters is 110 bar.
3.3.3
Lubricant amount
The cartridge contains 400 cm
3
of lubricant. The empty level is monitored by
an integrated reed contact.
3.3.4
Shelf life of Güdel H1 lubricant
The date of filling of the lubricant is shown on the lubricant cartridge. The
Güdel H1 lubricant has a shelf life of two years from date of filling. This ap-
plies to sealed original containers stored under the required storage condi-
tions.
Product description
OPERATING MANUAL Automatic lubrication system
FlexxPump 404DLS
99079191943154059_v10.0_
EN-US
30