8
Expert Net Control 2304
© 2021 GUDE Systems GmbH
Device Description
12. AC mains power supply
13. 8x relay switching contacts (NO)
Commissioning
·
Connect the device to the mains (100-240V AC) or to a plug-in power supply (12V to
24V AC, 12V to 30V DC).
·
Plug the network cable into the Ethernet socket (RJ45).
·
Connect the relays to the loads that are to be operated.
·
Establish contact between the lines to be monitored and the digital inputs.
·
Connect a sensor (if available).
1.4.1
Connection Example
Here is an example with block diagram in which the device is supplied with 230V AC
and in which eight AC loads (L1 - L8) are connected. In addition, the inputs are as-
signed eight switches (S1 - S8).