59
Expert Net Control 2302
© 2021 GUDE Systems GmbH
Specifications
A textual string containing name of a Relay Port.
enc2302PortState
.70.1.3.1.2.1.3.x
INTEGER
RW
current state a Relay Port
enc2302PortSwitchCount
.70.1.3.1.2.1.4.x
Integer32
RO
The total number of switch actions ocurred on a Relay Port. Does not
count switch commands which will not switch the ralay state, so just real
relay switches are displayed here.
enc2302PortStartupMode
.70.1.3.1.2.1.5.x
INTEGER
RW
set Mode of startup sequence (off, on , remember last state)
enc2302PortStartupDelay
.70.1.3.1.2.1.6.x
Integer32
RW
Delay in sec for startup action
enc2302PortRepowerTime
.70.1.3.1.2.1.7.x
Integer32
RW
Delay in sec for repower port after switching off
epc2302PortResetDuration
.70.1.3.1.2.1.8.x
Integer32
RW
Delay in sec for turning Port on again after Reset action
enc2302ActiveInputs
.70.1.5.6.1.0
Unsigned32
RO
Number of suppported Input Channels.
enc2302InputIndex
.70.1.5.6.2.1.1.x
Integer32
RO
None
enc2302Input
.70.1.5.6.2.1.2.x
INTEGER
RO
Input state of device
enc2302InputName
.70.1.5.6.2.1.32.x
OCTETS
RW
A textual string containing name of the Input
enc2302StopPressed
.70.1.5.12.0
INTEGER
RO
signals if Stop action active
epc2302NTPTimeValid
.70.1.5.15.1.0
INTEGER
RO
Show if valid Time is received
epc2302NTPUnixTime
.70.1.5.15.2.0
Unsigned32
RO
show received NTP time as unixtime (secs since 1 January 1970)
epc2302NTPLastValidTimestamp
.70.1.5.15.3.0
Unsigned32
RO
show seconds since last valid NTP timestamp received
enc2302SensorIndex
.70.1.6.1.1.1.x
Integer32
RO
None
enc2302TempSensor
.70.1.6.1.1.2.x
Integer32
RO
actual temperature
enc2302HygroSensor
.70.1.6.1.1.3.x
Integer32
RO
actual humidity
enc2302InputSensor
.70.1.6.1.1.4.x
INTEGER
RO
logical state of input sensor
enc2302AirPressure
.70.1.6.1.1.5.x
Integer32
RO
actual air pressure
enc2302DewPoint
.70.1.6.1.1.6.x
Integer32
RO
dew point for actual temperature and humidity
enc2302DewPointDiff
.70.1.6.1.1.7.x
Integer32
RO
difference between dew point and actual temperature (Temp -
DewPoint)
enc2302ExtSensorName
.70.1.6.1.1.32.x
OCTETS
RW
A textual string containing name of a external Sensor
4.7
SSL
TLS Standard
The device is compatible with TLS v1.1 to TLS v1.3 standards, but due to lack of se-
curity, SSL v3.0, TLS 1.0, and RC4, MD5, SHA1, and DES encryption are disabled. All
ciphers use Diffie-Hellman key exchange (Perfect Forward Secrecy).
TLS 1.3 performance
The interaction of TLS 1.3 and unsecure certificates and a web browser with Chro-
mium Engine (Google Chrome or MS Edge) can lead to performance losses, and thus
longer loading times. In this constellation, the Chromium Engine does not correctly
support the SSL Session Cache (Session Tickets) and the math unit of the embedded
CPU may be overwhelmed with continuous RSA operations. There are some possible
workarounds:
·
Use secure certificates (official certificate authority or marked as secure in the OS)
Summary of Contents for Expert Net Control 2302
Page 1: ...Manual Expert Net Control 2302 2021 GUDE Systems GmbH Manual Ver 1 3 0 from Firmware Ver 1 3 ...
Page 2: ...2 Expert Net Control 2302 2021 GUDE Systems GmbH ...
Page 5: ...Device Description ...
Page 13: ...Operating ...
Page 23: ...Configuration ...
Page 51: ...Specifications ...
Page 82: ...Support ...