epc8291BankPow erSource
.98.1.5.8.1.2.x
Integer32
RW
Pow er Source of Port Bank
epc8291BankPow erVoltage
.98.1.5.8.1.3.x
Gauge32
RO
Actual Voltage of Port Bank
epc8291BankPow erCurrent
.98.1.5.8.1.4.x
Gauge32
RO
Actual Current of Port Bank
epc8291Pow erSourceIndex
.98.1.5.9.1.1.x
Integer32
RO
None
epc8291Pow erSourceVoltage
.98.1.5.9.1.2.x
Gauge32
RO
Actual Voltage of Pow er Source
epc8291Pow erSourceCurrent
.98.1.5.9.1.3.x
Gauge32
RO
Actual Current of Pow er Source
epc8291CPUSensorVsystem
.98.1.5.14.1.0
Gauge32
RO
System Voltage on CPU Board
epc8291CPUSensorVaux
.98.1.5.14.2.0
Gauge32
RO
Auxiliary Voltage on CPU Board
epc8291CPUSensorVmain
.98.1.5.14.3.0
Gauge32
RO
Main Voltage on CPU Board
epc8291CPUSensorTcpu
.98.1.5.14.4.0
Integer32
RO
Temperature on CPU Board
epc8291NTPTimeValid
.98.1.5.15.1.0
INTEGER
RO
Show if valid Time is received
epc8291NTPUnixTime
.98.1.5.15.2.0
Unsigned32
RO
show received NTP time as unixtime (secs since 1 January 1970)
epc8291NTPLastValidTimestamp
.98.1.5.15.3.0
Unsigned32
RO
show seconds since last valid NTP timestamp received
epc8291SensorIndex
.98.1.6.1.1.1.x
Integer32
RO
None
epc8291TempSensor
.98.1.6.1.1.2.x
Integer32
RO
actual temperature
epc8291HygroSensor
.98.1.6.1.1.3.x
Integer32
RO
actual humidity
epc8291AirPressure
.98.1.6.1.1.5.x
Integer32
RO
actual air pressure
epc8291Dew Point
.98.1.6.1.1.6.x
Integer32
RO
dew point for actual temperature and humidity
epc8291Dew PointDiff
.98.1.6.1.1.7.x
Integer32
RO
difference betw een dew point and actual temperature (Temp -
Dew Point)
epc8291ExtSensorName
.98.1.6.1.1.32.x
OCTETS
RW
A textual string containing name of a external Sensor
4.6
SSL
TLS Standard
The device is compatible with TLS v1.1 to TLS v1.3 standards, but due to lack of secur-
ity, SSL v3.0, TLS 1.0, and RC4, MD5, SHA1, and DES encryption are disabled. All
ciphers use Diffie-Hellman key exchange (Perfect Forward Secrecy).
TLS 1.3 performance
The interaction of TLS 1.3 and unsecure certificates and a web browser with Chromium
Engine (Google Chrome or MS Edge) can lead to performance losses and thus longer
loading times. In this constellation, the Chromium Engine does not correctly support the
SSL Session Cache (Session Tickets) and the math unit of the embedded CPU may be
overwhelmed with continuous RSA operations. Possible workaround:
Summary of Contents for Expert Power Control 8291
Page 2: ...2 Expert Power Control 8291 2020 GUDESystems GmbH ...
Page 5: ...Device Description ...
Page 16: ...Operating ...
Page 26: ...Configuration ...
Page 52: ...Specifications ...
Page 85: ...Support ...