Guardian 04630 Instruction Manual Download Page 1

 

 

 

 

 

 

 

GUARDIAN FALL PROTECTION 

 26513 

79

th

 Ave. E. 

 

  

 

Kent, WA  98032 

 

Phone (800) 466-6385  Fax (800) 670-7892  

 

 

1

 

 

 
 
 
 

 
 
 
 

USER’S INSTRUCTION MANUAL FOR THE INSTALLATION,  

OPERATION & MAINTENANCE OF THE  

GUARDIAN

 04630 TEMPORARY HORIZONTAL LIFELINE 

SYSTEM

 

 
 

 

 
 
 

Summary of Contents for 04630

Page 1: ...LL PROTECTION 26513 79th Ave E Kent WA 98032 Phone 800 466 6385 Fax 800 670 7892 1 USER S INSTRUCTION MANUAL FOR THE INSTALLATION OPERATION MAINTENANCE OF THE GUARDIAN 04630 TEMPORARY HORIZONTAL LIFEL...

Page 2: ...S LABELS AND WARNINGS for each component part of the complete system before using it If you do not understand the Instruction Labels and Warnings for the use and maintenance of this component have the...

Page 3: ...to stationary anchorage points I Beam Clamps Pipe Rack Stanchion Systems or Steel I Beam Post Systems This system has been designed and tested to be used with Guardian Personal Fall Arrest Equipment P...

Page 4: ...l with corrosion resistant finish Minimum Breaking Strength 5 600 lbs Anchor Slings Material of Construction Web Polyester Small D Ring Drop forged alloy steel Standard finish cadmium Large D Ring Pla...

Page 5: ...le to support 3 600 lbs in all directions of a potential fall Anchorage Connectors Connectors must be capable of holding 5 000 lbs without breaking Connectors must be compatible with the connection po...

Page 6: ...is necessary to work around these types of surfaces always use a wear pad or barrier Clearance There must be sufficient clearance beneath the structure to ensure that workers do not contact an obstruc...

Page 7: ...bstruction with Guardian 6 Shock Absorbing Lanyard with One 1 or Two 2 Workers on Line Span Distance in feet Required Clearance Below Working Level for One 1 Worker in feet Required Clearance Below Wo...

Page 8: ...ion chemicals excessive heat flames electrical charge or shows signs of any physical damage or deformation Keep all labels on fall protection equipment readable Use this device if your total combined...

Page 9: ...stem Potential free falls may not exceed 6 ft To reduce free fall distance keep anchorage points above your working level Note ANSI A10 14 requires personal fall arrest systems to be rigged so that th...

Page 10: ...rectly to an approved anchor point 1 Wrap polyester anchor sling around one support structure Sling must be wrapped around column at least twice and fit up snugly against structure 2 Take one self loc...

Page 11: ...on and replacement of the system A record log of all servicing and inspection dates for this system should be maintained by the company safety officers at intervals of no less than twice per year This...

Page 12: ...s not been inspected in the last six months The label s is missing or illegible Alteration of any components Inspection reveals excessive wear cracks or signs of deformation Only Guardian manufacturin...

Page 13: ...fing abrasion melting and chemical wear 6 Inspect synthetic harnesses and lanyards for the same items outlined in 5 in addition to inspecting for discoloration damaged stitching and exposed warning la...