Component Function 

J15 

(Dynamic) Microphone Input  

R31 

Potentiometer for high frequency cutoff adjustment 

R22 

Potentiometer for low frequency cutoff adjustment 

J21 

Microphone output signal 

J20 

Receiver indicator output (LED can be mounted) 

J3 

Page/Talk output indicator (when the Page/Talk button is pressed these contacts 
J3-1; J3-2 are shorted) 

J1 

24V AC or DC input (pins 1 & 2) 

F1 

0.5 Amp fuse (fast blow) 

S1 

#3 alarm switch (contacts 1 - 5 of J5) 

S2 

#2 alarm switch (contacts 2 - 5 of J5) 

S3 

#1 alarm switch (contacts 3 - 5 of J5) 

S4 

Reset alarm switch (contacts 4 - 5 of J5) 

J14 

(Amplified) Page input signal 

R28 

Potentiometer for speaker volume adjust (on the PCB) 

J19 

Header for panel mount volume adjust speaker (R28 has to be removed) 

J13 Speaker 

output 

J4 

Mute speaker (1 - 2 mute on, 2 - 3 mute off) 

J2 

Phone line 1 in (header) [optional usage]  

J18 

Phone line 1 out (RJ11) [optional usage] 

J16 

Phone line 2 in (header) [optional usage] 

J17 

Phone line 2 out (RJ11) [optional usage] 

 

Table 1 - Circuit Board Connections 

Summary of Contents for PSCU

Page 1: ...Paging System Control Unit Model PSCU Installation Operation P006773 Rev C 151109 11 9 2015 12 45 PM Ph 403 258 3100 email info guardiantelecom com www guardiantelecom com...

Page 2: ...ineering Specifications 11 Warranty 12 Disclaimer 12 Warning 12 Service Number 12 Feedback 12 Guardian Product Return 13 Table of Figures Figure 1 Dimensions 4 Figure 2 Back View 4 Figure 3 Features 5...

Page 3: ...built in page system monitor speaker with respective volume control The PSCU is remote powered and connected to the main system rack via a 25 conductor cable Features 16 gauge steel enclosure zinc di...

Page 4: ...Guardian Telecom Inc Installation and Operation Model PSCU 220mm 8 7 151mm 6 0 298mm 11 7 203mm 8 0 Figure 1 Dimensions 1 Figure 2 Back View DB25 Connector Page 4...

Page 5: ...Indicator if not equipped with Recorder option Pilot Tone Generator Status Indicator Light Backup Power Amplifier Activated Indicator Light RF Detector Failure Indicator Light PTT Push to Talk Button...

Page 6: ...or DC input pins 1 2 F1 0 5 Amp fuse fast blow S1 3 alarm switch contacts 1 5 of J5 S2 2 alarm switch contacts 2 5 of J5 S3 1 alarm switch contacts 3 5 of J5 S4 Reset alarm switch contacts 4 5 of J5 J...

Page 7: ...Guardian Telecom Inc Installation and Operation Model PSCU Figure 4 Circuit Board Features Page 7...

Page 8: ...le noise on the PSCU monitor speaker The low frequency filter potentiometer R22 can help reduce any possible distortion to the PSCU monitor speaker Test all input outputs and audio according to system...

Page 9: ...Oil 1 Major 2 and Fire 3 Alarm switches are illuminated switches B Push to Page switch The Push to Page PTP switch is a heavy duty shrouded switch Pressing the PTP switch will activated the Microphone...

Page 10: ...RED GROUND 8 J6 1 ORG RED FIRE LED 9 J7 1 ORG MAJOR LED 10 J8 1 ORG GRN OIL LED 11 J8 2 ORG BLK GROUND 12 J20 1 GRN WH REC EN 13 J20 2 GRN BLK GROUND 14 J3 1 GRN PTT CONTACT A 15 J3 2 GRN BLK WH PTT...

Page 11: ...SUPPLY VOLTAGE 24 VDC FUSE 0 5 AMP TYPE 2AG FAST BLOW 70 V PAGE LINE INPUTS FREQUENCY RANGE 250 HZ TO 8 KHZ MICROPHONE PRE AMP OUTPUT FREQUENCY RANGE 250 HZ TO 8 KHZ SPEAKER OUTPUT FREQUENCY RANGE 25...

Page 12: ...arning This device has no user serviceable internal components the only maintenance possible is the replacement of the fuse which is available inside on the PCB Service Number 1 800 363 8010 Guardian...

Page 13: ...r by calling the service number given in this manual After providing information on the product the owner and the nature of the problem Guardian will issue a RMA number to be shown on documentation re...

Page 14: ...Guardian Telecom Inc Installation and Operation Model PSCU Page 14 Notes Model No Part No Serial No Date of Purchase...

Page 15: ...THIS PAGE INTENTIONALLY LEFT BLANK...

Page 16: ...Telecom Inc Toll free 1 800 363 8010 Phone 403 258 3100 Fax 403 253 4967 www guardiantelecom com E mail mailto sales guardiantelecom com Click to open message box CONNECTED PROTECTED Guardian Telecom...

Reviews: