background image

Guardian Telecom Inc. 

Installation and Operation 

Model PSCU 

2

1

4

3

5

6

7

8

10

11

12

9

RECORD

PILOT

BACKUP

RF FAIL

OIL

FIRE

RESET

VOLUME

 

Figure 3 - Features 

 

Record Activation Indicator Light 

(Console Power Indicator if not equipped with Recorder option) 

 

Pilot Tone Generator Status Indicator Light 

 

Backup Power Amplifier Activated Indicator Light 

 

RF Detector Failure Indicator Light 

 

PTT (Push-to-Talk) Button for PA Ov Recorder Control (if equipped) 

 

Console Monitor Speaker Volume Control 

 

Alarm Trigger #3 

 

Alarm Trigger #2 

 

Gooseneck Microphone 

 

Alarm Trigger #1

 

Alarm Reset Button

 

Console Monitor Speaker 

 

Page 5 

 

 

Summary of Contents for PSCU

Page 1: ...Paging System Control Unit Model PSCU Installation Operation P006773 Rev C 151109 11 9 2015 12 45 PM Ph 403 258 3100 email info guardiantelecom com www guardiantelecom com...

Page 2: ...ineering Specifications 11 Warranty 12 Disclaimer 12 Warning 12 Service Number 12 Feedback 12 Guardian Product Return 13 Table of Figures Figure 1 Dimensions 4 Figure 2 Back View 4 Figure 3 Features 5...

Page 3: ...built in page system monitor speaker with respective volume control The PSCU is remote powered and connected to the main system rack via a 25 conductor cable Features 16 gauge steel enclosure zinc di...

Page 4: ...Guardian Telecom Inc Installation and Operation Model PSCU 220mm 8 7 151mm 6 0 298mm 11 7 203mm 8 0 Figure 1 Dimensions 1 Figure 2 Back View DB25 Connector Page 4...

Page 5: ...Indicator if not equipped with Recorder option Pilot Tone Generator Status Indicator Light Backup Power Amplifier Activated Indicator Light RF Detector Failure Indicator Light PTT Push to Talk Button...

Page 6: ...or DC input pins 1 2 F1 0 5 Amp fuse fast blow S1 3 alarm switch contacts 1 5 of J5 S2 2 alarm switch contacts 2 5 of J5 S3 1 alarm switch contacts 3 5 of J5 S4 Reset alarm switch contacts 4 5 of J5 J...

Page 7: ...Guardian Telecom Inc Installation and Operation Model PSCU Figure 4 Circuit Board Features Page 7...

Page 8: ...le noise on the PSCU monitor speaker The low frequency filter potentiometer R22 can help reduce any possible distortion to the PSCU monitor speaker Test all input outputs and audio according to system...

Page 9: ...Oil 1 Major 2 and Fire 3 Alarm switches are illuminated switches B Push to Page switch The Push to Page PTP switch is a heavy duty shrouded switch Pressing the PTP switch will activated the Microphone...

Page 10: ...RED GROUND 8 J6 1 ORG RED FIRE LED 9 J7 1 ORG MAJOR LED 10 J8 1 ORG GRN OIL LED 11 J8 2 ORG BLK GROUND 12 J20 1 GRN WH REC EN 13 J20 2 GRN BLK GROUND 14 J3 1 GRN PTT CONTACT A 15 J3 2 GRN BLK WH PTT...

Page 11: ...SUPPLY VOLTAGE 24 VDC FUSE 0 5 AMP TYPE 2AG FAST BLOW 70 V PAGE LINE INPUTS FREQUENCY RANGE 250 HZ TO 8 KHZ MICROPHONE PRE AMP OUTPUT FREQUENCY RANGE 250 HZ TO 8 KHZ SPEAKER OUTPUT FREQUENCY RANGE 25...

Page 12: ...arning This device has no user serviceable internal components the only maintenance possible is the replacement of the fuse which is available inside on the PCB Service Number 1 800 363 8010 Guardian...

Page 13: ...r by calling the service number given in this manual After providing information on the product the owner and the nature of the problem Guardian will issue a RMA number to be shown on documentation re...

Page 14: ...Guardian Telecom Inc Installation and Operation Model PSCU Page 14 Notes Model No Part No Serial No Date of Purchase...

Page 15: ...THIS PAGE INTENTIONALLY LEFT BLANK...

Page 16: ...Telecom Inc Toll free 1 800 363 8010 Phone 403 258 3100 Fax 403 253 4967 www guardiantelecom com E mail mailto sales guardiantelecom com Click to open message box CONNECTED PROTECTED Guardian Telecom...

Reviews: