Guardian Telecom Inc. 

 

Installation and Operation 

Model AS12 

U S E

F

E

S

U

F

VOX

LOGIC INPUT

AMP. FAILURE

LOGIC OUTPUT

BACKUP

FAILURE

SPKR

OUTPUT

FROM

AMP. 1

SPKR

OUTPUT

FROM

AMP. 2

SPKR

OUTPUT

FROM

AMP. 3

SPKR

OUTPUT

FROM

AMP. 4

FROM 

BACKUP

AMP.

1 2 3 4 5 C

1 2 3 4 5 C

220 VAC

FUSE  1 A 

POWER

CHANNEL 1

CHANNEL 2

CHANNEL 3

CHANNEL 4

1

2

3

9

8

4

 

Figure 3 - Rear Panel 

 

1.  Power ON / OFF Switch. 
2.  Fuse, 1 Amp. 
3.  Power input for 120/230 VAC. 
4.  VOX Logic Input (from DA388). 
5.  Amplifier Failure Logic Output. 
6.  Audio Output to Speakers 1 – 4. 
7.  Audio Input from Amplifiers 1 – 4. 
8.  Audio Input from Backup Amplifier. 
9.  Logic Output for Backup Amplifier Failure. 

 

 

Page 5 

 

 

Summary of Contents for AS12

Page 1: ...e Automatic Amplifier Switch Model AS12 Installation and Operation VOX THRESHOLD ADJUSTMENT AMP 1 AMP 2 AMP 3 AMP 4 STAND BY AS 12 AMPLIFIER SWITCH RESET Guardian Telecom Inc P005093 Rev C 070518 7 21...

Page 2: ...mer 10 Warning 10 Service Telephone Number 10 Feedback 10 Guardian Product Return 11 Table of Figures Figure 1 Dimensions 4 Figure 2 Front Panel 4 Figure 3 Rear Panel 5 Figure 4 Block Diagram 6 Figure...

Page 3: ...integrated industrial emergency communications system the AS12 ensures uninterrupted communication in the event of an amplifier failure The AS12 Automatic Amplifier Switch is one component in Guardia...

Page 4: ...r LED See below 3 Fault History Reset Button 4 VOX Threshold Adjustments 5 Backup Threshold Adjustment 6 Backup Amplifier Status Indicator LED See below There are two Status Indicators The top one ind...

Page 5: ...MP 4 FROM BACKUP AMP 1 2 3 4 5 C 1 2 3 4 5 C 220 VAC FUSE 1 A POWER CHANNEL 1 CHANNEL 2 CHANNEL 3 CHANNEL 4 1 2 3 9 8 4 Figure 3 Rear Panel 1 Power ON OFF Switch 2 Fuse 1 Amp 3 Power input for 120 230...

Page 6: ...CHANNEL AUDIO OUTPUTS LOGIC INPUTS CHANNEL PRE AMP ACTIVE ALLOCATOR BACKUP CHANNEL DETECTOR FAIL CHANNEL CONTROL UNIT CH SB CH 4 CH 3 CH 2 CH 1 CH 4 CH 3 CH 2 CH 1 Figure 4 Block Diagram DA388 MIC 1...

Page 7: ...connected to the AS12 are turned off Follow all appropriate electrical codes for the installation Use the following sequence when wiring connections o Audio Inputs See Connection Details below o Cont...

Page 8: ...fails the standby amplifier will also fail Multiple Amplifier Failure If more than one amplifier fails at the same time the standby amplifier will only replace the highest priority the lowest numbered...

Page 9: ...Inputs 5V TTL LEVEL RECOMMENDED ACTIVATING DEVICES DRY CONTACT RELAY MINIMUM OPEN COLLECTOR OPEN DRAIN CURRENT CAPACITY 100mA Logic Outputs 4 Logic Open Drain Outputs OUTPUT SWITCH CURRENT CAPACITY 4...

Page 10: ...rnal components the only maintenance possible is the replacement of the fuse which is available from the back panel Service Telephone Number 1 800 363 8010 Guardian Telecom provides a customer service...

Page 11: ...ng the service telephone number given in this manual After providing information on the product the owner and the nature of the problem Guardian will issue a RMA number to be shown on documentation re...

Page 12: ...Calgary Alberta Canada T2E 8W1 Toll free 1 800 363 8010 Ph 403 258 3100 Fax 403 253 4967 www guardiantelecom com E mail mailto sales guardiantelecom com Click to open message box Industrial Communicat...

Reviews: