background image

DTN 80

Designed in German

| 04 | 02.2019

 

DIN

18650

EN1600

5

EN16005

eng

AutomAtic entrAnce systems

Swing-door drive

Operating instructions

Translation of the original Instructions

A

-7165140

 

Summary of Contents for DTN 80

Page 1: ...DTN 80 Designed in Germany 04 02 2019 DIN 18650 EN16005 EN16005 eng Automatic entrance systems Swing door drive Operating instructions Translation of the original Instructions A 7165140...

Page 2: ...e rated door 6 2 Safety instructions 7 2 1 General 7 2 2 Mandatory specifications 7 2 3 Applicable documents 10 3 Advice on safe operation of the swing door 11 3 1 Behaviour of the control unit 11 3 2...

Page 3: ...20 8 4 Spring operated key switch option 20 8 5 Manual release push button 20 8 6 RESET push button 20 9 Opening and closing behaviour safety 21 9 1 Automatic opening 21 9 2 Automatic closing 21 9 3 C...

Page 4: ...eaning 24 12 Maintenance activities of the operator 25 12 1 Testing a hold open system 26 13 Specialists 26 14 Inspection and after sales service 27 14 1 Testing and maintenance 27 14 2 Inspection and...

Page 5: ...n ergy Special work only to be carried out by qualified electricians Note use in the context of fire protection 1 1 Explanation of symbols The following warning messages are highlighted by special sym...

Page 6: ...xcludes any liability for damage arising from changes made to the system without its consent Once the swing door drive has been installed correctly it is then only suitable for standard opening and cl...

Page 7: ...fically to individual functional steps or activities can be found in the relevant sections of these operating instructions The swing door drive has been manufactured to current state of the art standa...

Page 8: ...lication limits specified by GU Automatic Permanent operation in the deenergised state is not permitted If the drive is used in the deenergised state outside of the usage limits in the diagram below o...

Page 9: ...cessary free space in the swing movement area of the doors so that correct functioning can be guaranteed at all times Scissor action arm and slide rail Please note that crushing and shearing risks are...

Page 10: ...amage to the power supply cable is identified the power plug must be removed from the socket outlet immediately The power supply cable must be replaced by a qualified electrician Signage Additional si...

Page 11: ...e control unit performs a system test at regular intervals This test causes an audible clicking sound When closed the swing door presses closed several times and conducts various tests Opening request...

Page 12: ...ent damage to the swing door drive and the hinges do not remove the doorstop Sensors Safety sensors are fitted to both sides of the swing door leaf as a safety measure when the door is opening or clos...

Page 13: ...show the possible elements on a swing door system 1 Swing door drive 2 PO3 programme switch 3 Radar motion sensor 4 Laser scanner 5 Sensor strip 6 POS 5 programme switch 7 Elbow push button 8 Opening...

Page 14: ...erating instructions eng Fire rated door 1 T r schlie en Taster red manual release push button 2 RESET push button 3 Smoke switch number depends on ceiling construction and height 4 Adhesive label Ach...

Page 15: ...lude e g SECURY Automatic A SECURY e Power and the motor driven shoot bolt lock These locks are activated by the swing door drive 6 2 Daytime release The setting of a daytime release makes it possible...

Page 16: ...e safety sensors Operation modes on the passive leaf With the PO3 see PO3 programme switch on page 19 of the passive leaf there are two options for pre setting Z Z Move switch PO3 of the passive leaf...

Page 17: ...r swing doors that usually should be locked but that can enable people to leave the building or areas of the building From outside only authorised people should be able to enter One possible applicati...

Page 18: ...page 15 It is possible to pass through manually Depending on the setting the swing door drive behaves like an overhead door closer or it compen sates for its spring force to support manual actuation 7...

Page 19: ...ed operation mode as shown in the graphic on the switch 8 Operating elements In the event of malfunctions please refer to Section Rectifying mal functions on page 22 spreadsheet column Remedy on page...

Page 20: ...d on the outside makes it possible to open the swing door from the outside even in OFF operation mode and even if the swing door is closed and locked This opening requirement is important for building...

Page 21: ...ately When the swing door leaf has been blocked the leaf is held against that obstacle The door closes automatically after the blockage has been cleared 9 3 Closing by spring force The swing door is o...

Page 22: ...vices respond When the swing door is released it closes automatically after at least 3 seconds 10 Faults 10 1 Power failure If the swing door is locked unlock it first Then the swing door can be opene...

Page 23: ...object and if necessary check for signs of mechanical damage Internal or external pulse transmitter defective If necessary engage PERMANENTLY OPEN operation mode and notify Service Safety sensor detec...

Page 24: ...the slide rail Cleaning the swing doors Glass Wash and wipe down using cold vinegar water or glass cleaner Untreated metal surfaces e g stainless steel Clean with a mild lye and a slightly damp non ab...

Page 25: ...isible on the floor near the system immediately shut it down Then call for a qualified after sales service specialist to conduct a thorough examination of the door Z Z Check that the swing door operat...

Page 26: ...oors and about the applicable health and safety at work H SW regulations directives and generally recognised rules of technology that they are in a position to evalu ate the operational condition of m...

Page 27: ...is once per year This mainte nance also includes checking that the safety function and devices function properly These regular inspections which take into account the specifications of the manufactur...

Page 28: ...ction must be carried out by hold open system specialists or per sons who have received appropriate training The scope outcome and timing of the annual inspection and maintenance must be recorded in t...

Page 29: ...r States relating to the making available on the market of electrical equipment designed for use within certain voltage limits recast 2014 30 EU EMC Directive Directive of the European Parliament and...

Page 30: ...30 DTN 80 02 2019 Designed in Germany Swing door drive Operating instructions eng Blank page...

Page 31: ...31 Blank page...

Page 32: ...ic de Errors and omissions reserved Subject to technical modifications GU Automatic GmbH Karl Schiller Stra e 12 D 33397 Rietberg Service Hotline 49 0 1805242111 Fax 49 0 52449075 585 E Mail service g...

Reviews: