Page 53
Issue 05/2013
Installation of generator
Installation of dual-bearing generators (BG 132)
Permissible load of the shaft
y
Standard bearing plate (shaft ø 28 mm)
Fr
max
= 2,000 N (measured in 50 mm axial
clearance from the point where the shaft exits
the bearing plate) Fa
max
= 200 N
y
Reinforced bearing plate (shaft ø 32 mm):
Fr
max
= 3,000 N (measured in 50 mm axial
clearance from the point where the shaft exits
the bearing plate) Fa
max
= 380 N
Important
►
Do not attach any third party parts to
the mounting profiles on the generator
housing.
6.7.2
Minimum clearances and cooling provisions
y
The generator needs sufficient ventilation for cooling. The cooling air is
drawn through the cooling profiles by the fan wheel on the rear side of the
generator and across the housing, towards the front side.
y
Ensure adequate air feed and exhaust openings.
y
During assembly, observe the minimum clearances and specifications for
cooling.
Minimum clearances
When installing, respect the following minimum
clearances from fixed parts or walls (ð adjacent
figures). In individual cases, the clearances
may vary from these figures. Get in touch with
Generator.Technik.Systeme GmbH & Co. KG.
y
On the side and top: a = 100 mm
y
Front: b = 200 mm
y
Rear: c = 170 mm
Fr
max
Fa
max
b
b
a
a
a