background image

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Signal Amplifier 

GTD-AMP8-R 

User’s Manual 

 

 

 

 

 

Guangzhou GTD Lighting Technology Co., Ltd. 

Tel: +86-20-61808296

 

Fax: +86-20-61812282 

http://

www.gtd-lighting.com

 

 

Summary of Contents for GTD-AMP8

Page 1: ...Signal Amplifier GTD AMP8 R User s Manual Guangzhou GTD Lighting Technology Co Ltd Tel 86 20 61808296 Fax 86 20 61812282 http www gtd lighting com ...

Page 2: ...panies and are hereby acknowledged All non GTD brands and product names are trademarks or registered trademarks of their respective companies GTD and all affiliated companies hereby disclaim any and all liabilities for property equipment building and electrical damages injuries to any persons and direct or indirect economic loss associated with the use or reliance of any information contained with...

Page 3: ...ns 3 General guidelines 4 Packing and shipping 4 Unpacking 4 Packing after use 4 Accessories 4 Product introduction 5 Power Control connection 5 Testing 5 Control panel 6 Technical specification 7 System wiring diagram 7 Spare parts list 8 Appendix 1 8 ...

Page 4: ...re hazard INDOORS USE ONLY Do not expose fixture for rain and moisture It s essential that the fixture is properly grounded Only qualified personnel should perform electrical connections WARNING The antenna of the fixture must be installed in a correct way Be sure to keep the minimum safe distance of 20cm 7 9 in with the personnel Only qualified and certified personnel should perform installation ...

Page 5: ... technical personnel or call the service hotline 8620 61808296 Packing and shipping Unpacking Notes All products are quality controlled and checked for any faults before they are dispatched to customers If the fixture is damaged during delivery the customer must notify the shipper and manufacturer to file a damage insurance claim Photographic evidence of the damage must be provided Cardboard box O...

Page 6: ... 4 Power input 5 DMX output female 6 DMX input male 7 DMX input female Power Control connection The fixture has 5 pin or 3 pin XLR connectors for DMX data input and output Testing Connect the fixture to AC power Check if the LED indicator see next page for details is on before putting into operation ...

Page 7: ...open space Interface type 5 or 3 pins XLR can be selected Signal isolation DMX512 signal input DMX signal output power and signal are isolated Wireless antenna must be pointing upwards when in use see below Wireless function description Device When using the wireless receiving function the necessary devices are DMX512 console wireless transmitter and lighting equipments Connection Connect the fixt...

Page 8: ...n receiver with transmitter when it can establish communication with any transmitter Press FUNCTION button on the receiver 5s to erase the communication memories of the receiver with transmitter when wireless signal indicator of the lamp turns red and flash slowly Technical specification Structure Metal materials structure and can be installed in any safe position Power input nominal AC 200 240V 5...

Page 9: ... W DMX A40895G5 A NANO RX PCB Transformer assembly 5103050239A 1 B25172N1 27VA XLR board 502 1 5802910024A 1 SKL0502B XLR board 503 1 5802910025A 9 SKL0503B Console board 0506A 1 5802913002A 1 SKT0506A Console board 0500B 1 5802913003A 1 SKT0500B Console board 0501C 1 5802913004A 1 SKT0501C Appendix 1 ...

Page 10: ...GTD AMP8 R User Manual 9 Notes P N 1502011069A Time March 23th 2017 ...