1.  Overview     

S-9102R  Stand  Alone  Smoke  Detector  (here 

called  smoke  detector  for  short)  detects  smoke 

produced  by  a  fire  and  gives  alarm  signals  in 

time.   

Using  optical  smoke  sensing  parts  and  art  of 

state  production  technologies,  it  has  a  stable 

performance,  esthetical  appearance  and can be 

easily  installed,  no  commission  required.  It  is 

designed  to  monitor  fires  may  occur  in  places 

such  as  houses,  all  kinds  of  shops,  pubs,  bars 

and etc. 

Built-in  a  buzzer  can  give  an  alarming  sound 

aloud  and  silence  it.  Two  AA  1.5V  LR6  alkaline 

batteries will be operating up to three years.   

2.  Technical Specifications   

1) 

Power supply: 2 AA 1.5V LR6 alkaline 

batteries, operates up to 3 years or so.   
2) 

Indicator: Red, flashes in every 45 

seconds in normal condition. 

3) 

Sound Level

80dB@3m 

4) 

Switch output terminals C+, C- 

(polarity-sensitive):   

External maximum voltage: 30V   

Maximum current: 60mA 

5) 

Detection Area: 60m

~100m

2

 

6) 

Operating Environment: 

Temperature: -10

 ~ +50

 

Relative Humidity

≤ 95%, non- condensing 

7) 

Dimension: 120mm x 58mm(D x H, with 

base) 
8) 

Material of Enclosure: ABS 

9) 

Weight: 181g(without base) 

10) 

Mounting Hole Distance: 50mm~74mm 

3.  Installation and Wiring 

3.1. Location of Smoke detectors 

One  smoke  detector  should  be  installed  in  an 
individual room. Refer to Fig. 1.

 

 

 

 

 

 
 

S-9102R Stand Alone Smoke Detector 

 

   

 

 

 

 

 

 

 

 

 

 

Fig. 1 

3.2. Mounting Position   

1) Recommended Location   

The  position  of  a  smoke  detector  is  critical  if 
maximum speed of fire detection is desired. This 
smoke  detector  can  be  mounted  on  a  ceiling  or 
wall. Thus, the best location for a smoke detector 
is  the  center  of  the  ceiling.  At  this  location,  the 
smoke  detector  is  closest  to  all  areas  of  the 
room. 

  When  mounted  on  ceilings,  the  edge  of  the 

smoke  detector  should  be  at  least  50cm  to 
any wall. 

  When  mounted  on  slope  or  gable  roof,  the 

smoke  detector  should  keep  a  certain 
distance from the roof. The distance should be 
0.2m  when  slope  angle  is  less  than  30

.  It 

should  be  0.3m

0.5m  if  the  angle  is  more 

than 30

2) Locations to avoid 

To  avoid  false  alarms,  do  not  install  smoke 
detectors: 

  In  or  near  areas  where  combustion  particles 

are  normally  present  such  as  kitchens.  In 
garages  where  there  are  particles  of 
combustion 

in 

vehicle 

exhausts. 

Near 

furnaces, water heater, or gas space heaters. 

The smoke detectors should be installed at 
least  6  meters  away  from  kitchens  and 
other  areas  where  combustion  particles 
are normally present. 

  In air streams passing by applications such as 

kitchens. 

  In  damp  or  very  humid  areas,  or  next  to 

bathrooms  with  showers.    The  moisture  in 
humid  air  may  cause  false  alarm.   

Install 

smoke  detectors  at  least  3  meters  away 
from bathrooms

   

Issue.1.02          August, 2014 

Room 

Room 

Room 

Room 

Room 

Room 

Hall 