- 11 -
STIM 1916 CT
3.4 C
onneCting
the
deviCe
• Connect the data input
1
to the LAN network via a CAT-6 cable.
—> The device requests the required multicast IP streams via the data in-
put every 60 seconds.
Querier requests will not be answered!
Keep
this in mind when configuring the network (Querier host timeout
> 60s).
—> You will find descriptions to important terms for configuring a
streaming network in menu
Help > Multicast Setup
.
• Connect the attached mains cables to the IEC connectors C14
15
.
—> The power cables are equipped with lockable C13 connectors. Re-
move the connectors by pulling back the red locking pin.
• Connect the mains cables to mains sockets with protective conductor con-
nections. Thereby note the voltage specified on the device.
—> This device has no primary power switch and is in standby mode im-
mediately after connecting the operating voltage. Power ON/OFF
8
switches only the secondary DC voltages!
For a complete disconnection from the mains, both mains plugs must
be pulled out of the mains sockets. Ensure that the mains plugs can
be pulled out without difficulties.
• Configure the device (page 14).
If you want permanent access to the device after the initial configuration, con-
nect one of the two Control ports
7
to a LAN network via a CAT-6 cable (for
remote access with Internet connection).
—> The two Control connectors must not be connected to an external
switch at the same time (looping). The second LAN socket is used to
connect another head-end station.
• If the
configuration is finished
connect the RF output
20
to the cable network.