The transport stream fed via the ASI socket can be inserted into the transport
streams of the receiving stages via the TPS module. The signal path is set in the
menu items input signal path “
INROUTE
” and output signal path ”
OUTROUTE
”.
2.4.1 Input signal path “INROUTE”
2.4.1.1 Menu setting “A+ASI=1 B+ASI=2”
The transport streams of the receiving stage of channel strip ”
A
” “TS
A
” and of
the ASI input “TS
ASI
” generate the transport stream 1. The transport streams
of the receiving stage of channel strip ”
B
” “TS
B
” and of the ASI input “TS
ASI
”
generate the transport stream 2.
2.4.1.2 Menu setting “A+B+ASI=1 ASI=2”
The transport streams of the receiving stages of channel strips ”
A
” “TS
A
”,
”
B
” “TS
B
” and of the ASI input “TS
ASI
” generate the transport stream 1. The
“TS
ASI
” transport stream fed via the ASI input generates the transport stream 2.
Transport stream 1
Transport stream 2
ASI input
Empfangsteil
"
A
"
Receiving stage
channel strip "
A
"
SAT IF
input ”
A
“
Receiving stage
channel strip "
B
"
SAT IF
input ”
B
“
TPS
TPS
TS
ASI
TS
A
TS
B
CA module
ASI input
Empfangsteil
"
A
"
SAT IF
input ”
A
“
TPS
TS
ASI
TS
A
TS
B
CA module
SAT IF
input ”
B
“
Receiving stage
channel strip "
A
"
Receiving stage
channel strip "
B
"
Transport stream 1