Installing the Roof Ring
Quantity and part numbers of roof ring kits vary with the location placement and with the size of each bin.
The following procedure will be similar for each kit.
1. Determine the quantity of roof ring clips (C) needed for the roof ring section (B) being installed.
NOTE:
Each roof panel rib must have a roof ring clip (C) installed.
2. Install a 5/16 x 1 in. flange bolt (A) to the roof ring clip (C) and install a sealing washer (E) to the
underside of the roof ring clip (C).
3. Slide each assembled roof ring clip (C) onto a roof ring section (B) and position each roof ring clip
(C) over each roof panel rib.
4. Install a 5/16 in. flange nut (D) to each roof ring clip (C).
NOTE:
Do not tighten hardware until all roof ring sections (B) have been installed.
Figure 8-10
Installing the roof ring
A
5/16 in. x 1 in. flange bolt with sealing washer (S-10260)
D
5/16 in. flange nut (S-3611)
B
Roof ring section (CRP-5363-XX)
6
E
Sealing washer (S-10303)
C
Roof ring clip (R-997)
5. Locate a threaded stud (F) and install stud nuts (G) evenly and to the center of the threaded
stud (F).
6. Install the threaded stud (F) with stud nuts (G) to the end of the roof ring section (B).
NOTE:
Install the threaded stud (F) to the side where the next roof ring section will be installed.
7. Repeat this process, installing each new roof ring section (B) end onto the preceding threaded stud
(F) just installed.
PNEG-4936
36 Ft. TopDry Autoflow
103
6.
(-XX) denotes the bin diameter.
Summary of Contents for TopDry Autoflow
Page 6: ...NOTES 6 PNEG 4936 36 Ft TopDry Autoflow...
Page 26: ...NOTES 26 PNEG 4936 36 Ft TopDry Autoflow...
Page 46: ...NOTES 46 PNEG 4936 36 Ft TopDry Autoflow...
Page 106: ...NOTES 106 PNEG 4936 36 Ft TopDry Autoflow...
Page 128: ...NOTES 128 PNEG 4936 36 Ft TopDry Autoflow...