Smart Climate 310 rev. 03 85
Identifying a Defective Probe Alarm
1. Press the
Current Conditions
button.
2. Press the current condition's down-arrow key. Probe
readings are then displayed. Dashes are displayed instead
of a reading when the probe is defective. In the case of
room temperature probes, the controller will operate
according to the temperature of the remaining probes.
Water Spill Alarm
A water spill alarm is set off when the water consumption exceeds
a certain limit. This limit can be adjusted from 0 to 1,000 gallons or
liters per 15 minutes. The alarm is activated if a greater quantity of
water is detected within the 15 minute delay. In addition, the
maximum allowable amount of water may be set differently for day
and night.
To set the maximum amount of water, proceed as follows:
1. Press
Alarms
.
2. Press the down-arrow key in order to select the
Water
Spill Set 1
display.
Available if the water meter is enabled in the USER SETUP.
3. Press
Adjust
. The maximum allowable water quantity for
set 1 flashes on the display.
4. Use the arrow keys to adjust the first water spill limit to the
desired value.
5. Press
Adjust
once again to validate.
6. Press the down-arrow key. The time at which the first
water spill setting starts being used is displayed.
7. Press
Adjust
then use the arrow key to specify range of
time.
8. Press
Adjust
once again to validate.
9. Press the down-arrow key and proceed in similar fashion
to adjust the water spill limit and the range of time for the
second water spill limit.
When there is a Water Spill alarm, you may reset the alarm as
follows.
1. Press
Alarms
.
Summary of Contents for Smart Climate 310
Page 1: ...Smart Climate 310 User s Guide 895 00676 REV 04 890 00582 REV 03...
Page 96: ...96 Smart Climate 310 rev 03 Probe Assignment...
Page 97: ...Smart Climate 310 rev 03 97 User Setup Menu...
Page 98: ...98 Smart Climate 310 rev 03...
Page 101: ...Smart Climate 310 rev 03 101 3 Press on the card and make it clip to the main board...
Page 102: ...102 Smart Climate 310 rev 03...