Smart Climate 310 rev. 03 77
Adjusting High and Low Pressure Set Points
The static pressure compensation starts when the static pressure
level exceeds the High or Low static pressure set points. The
controller can use two groups of pressure set points and chooses
the group of set points according to the ventilation stage in use.
To adjust High and Low pressure set points, proceed as follows:
1. Press
Compensations
.
This menu is accessible if a compensation function is enabled in the
USER SETUP menu.
2. Press the down-arrow key to display the first group of
static pressure set points (SP1 Low & SP1 High).
These parameters are accessible if the static pressure compensation
function is enabled in the USER SETUP.
3. Set the following parameters:
The parameters below are common to all air inlets (including 0-10V
inlets).
Lo SP1 / Hi SP1
: Set the high and low static pressure set points
for the first group of pressure set points and then press the down-
arrow key to step to the next parameter.
Lo SP2/ Hi SP2
: The controller can use two groups of pressure set
points and chooses the group of set points according to the
ventilation stage in use. Set the low and high static pressure set
points for the second group of set points then press the down-
arrow key to step to the next parameter. *It is possible to disable
the second group of pressure set points (see next parameter).
SP2 Starts at Stage
: Set the fan stage at which the second group
of static pressure set points starts. To disable the second group of
set point, increase the stage number until the word "None" is
displayed.
Use SP Comp on stage x?:
Determines on which stages the SP
compensation must be applied.
Limit SP comp to 4 times?
Determines if the compensation cycle
must be repeated as needed in order for the pressure to return to
normal or if it must be repeated up to four consecutive times.
Wind Effect Delay
: When the static pressure level exceeds the
normal range (above the Hi Pressure Set point or below the Lo
Pressure Set Point), the controller waits for the
Wind Effect
Delay
to make sure the pressure condition is not temporary. Set the wind
delay to the desired value (from 0 to 900 seconds).
Summary of Contents for Smart Climate 310
Page 1: ...Smart Climate 310 User s Guide 895 00676 REV 04 890 00582 REV 03...
Page 96: ...96 Smart Climate 310 rev 03 Probe Assignment...
Page 97: ...Smart Climate 310 rev 03 97 User Setup Menu...
Page 98: ...98 Smart Climate 310 rev 03...
Page 101: ...Smart Climate 310 rev 03 101 3 Press on the card and make it clip to the main board...
Page 102: ...102 Smart Climate 310 rev 03...