Selecting the Precision Level for Actuators
A minimum moving signal is required for the controller to start
moving an air inlet, which prevents actuators from flickering. The
minimum moving signal can be more or less precise, depending on
the type of actuator you are using.
The switch block marked
Controller Function
in the auxiliary
module allows setting the precision level. Set internal switches 5
and 8 correctly to select the wanted precision level (see table
below).
NOTE:
When the desired inlet opening is greater than 94%, the
moderate precision level will be automatically applied,
regardless of the positions of the switches.