Dump Mode:
When the temperature increases above the last ventilation stage,
the air inlet position is maintained. When the temperature reaches
"temperature
of the last reference point + #of degrees to max.
opening", the inlet opens to its maximum opening at once.
Opening Compensation based on the
Temperature
Compensation can be used to ensure a certain uniformity in the
room temperature. With this compensation, inlet positions are
automatically adjusted when the reading of inlet probes differs from
the ambient temperature reading. Note that this feature only
applies to air inlets and not to chimney dampers.
The temperature compensation of the air inlet is expressed as a
percentage per degree difference between the ambient
temperature and the average reading of the inlet’s probes. It
determines by how much an inlet must open or close to help
reduce the temperature differences in the building.