52 Smart Climate 310 rev. 03
Limiting Mist Shutoff
The controller can disable mist units when the humidity level is too
high to avoid increasing the humidity level any further. The mist
shutoff limit can be adjusted from 40 to 99% of relative humidity (or
select
Off
to disable this function).
To disable the mist units, proceed as follows:
1. Press
Mist
.
Accessible if mist units are enabled in the USER SETUP.
2. Press the down-arrow key in order to display the
Mist
Shutoff
parameter.
3. Press
Adjust
. The shutoff limit flashes on screen. Set
it to the desired value with the adjustment buttons. Mist
shutoff at 95%
Summary of Contents for Smart Climate 310