40 Smart Climate 310 rev. 03
Setting the Bandwidth
The bandwidth defines the interval over which a variable output
increases in speed, proportionally to the temperature (see previous
diagram). It can be adjusted between 0.5°F and 20.0°F (0.3°C and
11.1°C).
NOTE:
The first fan stage performed by the controller is the
variable stage assigned for minimum ventilation, which is not
necessarily stage 1
NOTE:
The number of stages displayed in the following menu is
limited by the maximum fan stage selected at the beginning of
this section.
To set the bandwidth, proceed as follows:
1. Press
Stages
.
2. Press the down-arrow key once. The bandwidth of the 1
st
variable fan stage is displayed. (The number displayed on
screen refers to the stage number).
3. Press
Adjust
and then use the arrow keys to set the
bandwidth to the desired value.
4. Press the down-arrow key again to select the winter's
bandwidth of the 1
st
variable fan stage (if applicable).
5. Press
Adjust
and then use the arrow keys to set winter's
bandwidth to the desired value.
6. Repeat steps 1 to 5 to set additional bandwidths.