32 Smart Climate 310 rev. 03
Low T° Override Functions
The controller can lower the minimum ventilation speed when the
room temperature gets too cold. Refer to the User Setup menu to
enable low temperature override functions.
Selecting the Minimum Ventilation Stage
Select which variable fan stage is used to provide minimum
ventilation (refer to the previous section for further information).
1. Press
Minimum Ventilation
. The minimum ventilation
stage is displayed.
2. Press
Adjust
. The stage starts flashing.
3. Use the arrow keys to select the desired variable stage
and press
Adjust
again to validate.
Adjusting the Minimum Ventilation Speed
This section shows how to set the speed of the variable fans that
are used in minimum ventilation.
1. Press
Minimum Ventilation
.
2. Press the down-arrow key in order to select the minimum
ventilation speed of the first variable fan output.
Only variable outputs that are assigned in variable mode are
available (see variable output assignment).
3. Press
Adjust
. The fan speed starts flashing.
4. Use the arrow keys to set the speed and press
Adjust
again to validate.
5. If the minimum ventilation stage uses another variable
output, press the down arrow key to select it.
6. Repeat steps 1 to 5 to set the minimum ventilation speed
of all variable outputs that are used in minimum ventilation.
Summary of Contents for Smart Climate 310
Page 1: ...Smart Climate 310 User s Guide 895 00676 REV 04 890 00582 REV 03...
Page 96: ...96 Smart Climate 310 rev 03 Probe Assignment...
Page 97: ...Smart Climate 310 rev 03 97 User Setup Menu...
Page 98: ...98 Smart Climate 310 rev 03...
Page 101: ...Smart Climate 310 rev 03 101 3 Press on the card and make it clip to the main board...
Page 102: ...102 Smart Climate 310 rev 03...