![GSi Smart Climate 310 User Manual Download Page 23](http://html1.mh-extra.com/html/gsi/smart-climate-310/smart-climate-310_user-manual_2274990023.webp)
Smart Climate 310 rev. 03 23
Automatic Relay Assignment
The controller automatically assigns a relay to each on/off stage
that is enabled in the
User Setup
menu. The table below shows
how the relays are assigned for each possible stage combination.
* On/off fan relays are assigned in numerical order: the first stage
uses relay 1, the second stage uses relay 2, etc. However, the first
On/off fan stage does not correspond to stage 1 but to the stage
number that follows the last variable fan stage.
For example, if fan stage 2 is used for minimum ventilation, the first
on/off fan stage is fan stage 3 and it uses relay 1.
Summary of Contents for Smart Climate 310
Page 1: ...Smart Climate 310 User s Guide 895 00676 REV 04 890 00582 REV 03...
Page 96: ...96 Smart Climate 310 rev 03 Probe Assignment...
Page 97: ...Smart Climate 310 rev 03 97 User Setup Menu...
Page 98: ...98 Smart Climate 310 rev 03...
Page 101: ...Smart Climate 310 rev 03 101 3 Press on the card and make it clip to the main board...
Page 102: ...102 Smart Climate 310 rev 03...