11
Installing the Stiffener Flashing
Support
1. Install the floor and support system, cutting the floor to go around the internal stiffeners as required.
2. Break the stiffener flashing support (24) into its three components.
3. Lay the stiffener flashing supports (24) on top of the flooring (23) and weld the flashing supports (24)
to the stiffener (22) as close as possible. Fasten the flashing to the wall, flashing support (24) and
floor. Seal all spaces by welding or caulking.
4. Paint all welds with good quality zinc rich paint.
5. Stiffener flashing supports (24) must be ordered separately from the standard floor and flashing.
Figure 11-1
Internal universal stiffeners
22
Stiffener
24
Stiffener flashing support (SS-6984)
23
Top of floor
PNEG-223