Installing the Flashing Lock
The flashing lock will need to be installed to secure the roof flashing and the top panel.
1. Position the flashing lock (A) under the roof flashing (B) aligning with the holes in the top panel (C)
from the underside of the roof.
NOTE:
Ensure the roof flashing (B) is inserted between the top panel (C) and the flashing lock (A).
2. Install the flange nuts (D) and flange nuts (E) to secure the top panel (C) with the flashing lock (A).
3. Repeat the procedure to install the remaining flashing locks.
4. Tighten all the hardware to the recommended specifications. See
Bolt Torque Specifications, page
.
Figure 8-39
Installing the flashing lock
A
Flashing lock (CTR-1588)
D
3/8 x 1 in. flange bolt with sealing washer (S-
7487)
B
Roof flashing (CTR-1574)
E
3/8 in. flange nut (S-9426)
C
Top panel (CTR-1585)
136
PNEG-4472
72 Ft Diameter Z-Tek Bins