Laminated Base Stiffener (2 Ga) with Insert (2+12 to 2+10 Ga) to a
Base Boot
Reference the following information when connecting a laminated base stiffener with insert (CTS-4034XX
and CTS-4037XX) to a base boot (CTS-4045XX or CTS-4048XX).
A
Laminated base stiffener (CTS-4034XX)
B
Base Insert (CTS-4037XX)
C
Base boot (CTS-4045XX or CTS-4048XX)
D
3/8 x 1 in. flange bolt (S-7485)
E
3/8 in. flange nut (S-9426)
F
Completed assembly
NOTE:
Only place bolts where holes in the stiffeners align
with holes in the sidewall sheet.
Standard Stiffener to a 12–Bolt Pattern Laminated Stiffener with
Insert
Reference the following information when connecting a standard stiffener (CTS-4002XX) to a 12–bolt pat-
tern laminated stiffener (CTS-4041XX) with insert (CTS-4042XX).
A
Standard stiffener (CTS-4002XX)
B
Laminated stiffener (CTS-4041XX)
C
Insert (CTS-4042XX)
D
3/8 x 1 in. flange bolt (S-7485)
E
3/8 in. flange nut (S-9426)
F
Completed assembly
NOTE:
Only place bolts where holes in the stiffeners align
with holes in the sidewall sheet.
PNEG-4336
36 Ft. Diameter 40-Series Bins
59