5. Troubleshooting
PNEG-1813
Electronic Distributor Control
49
5. Troubleshooting
Error Messages
Message:
The value entered was greater than the allowable deviation from the original position. Please enter
a value between X and Z.
Reason:
This error is displayed when a position count value outside the acceptable range is entered while in the
“Modify Spout Position” screen.
Remedy:
Enter a value between X and Z on the “Modify Spout Position” screen.
Message:
WARNING! Any changes to the settings will alter factory defaults and may result in damage to
equipment. To exit without changes, select CLOSE and then OK.
Reason:
This message is displayed as you enter the “Configuration Setup” screen.
Message:
The Home proximity sensor was not detected. The homing process failed. Please check for proper
operation of the sensor.
Reason:
This error is displayed when attempting to perform a “Homing” operation and the controller fails to receive
a proximity sensor signal before the time out period is reached.
Remedy:
Check wiring, wiring connections, and proximity sensors. Repair or replace as necessary.
Message:
The position feedback does not match expected behavior. Please check for proper operation of
the encoder.
Reason:
This error is displayed if the spout does not reach the desired position count while performing a “MOVE”
operation.
Summary of Contents for PNEG-1813
Page 2: ...2 PNEG 1813 Electronic Distributor Control ...
Page 4: ...Table of Contents 4 PNEG 1813 Electronic Distributor Control ...
Page 46: ...3 Operation Procedures 46 PNEG 1813 Electronic Distributor Control NOTES ...
Page 47: ...PNEG 1813 Electronic Distributor Control 47 4 Parts Distributor Assembly ...
Page 48: ...4 Parts 48 PNEG 1813 Electronic Distributor Control NOTES ...
Page 52: ...5 Troubleshooting 52 PNEG 1813 Electronic Distributor Control NOTES ...
Page 56: ...6 Schematic and Wiring Diagrams 56 PNEG 1813 Electronic Distributor Control NOTES ...