1. Safety
PNEG-1901CE
CE Compliant Downwind Centrifugal Heater Installation and Operation
7
Correct Use
The heater shall be used ONLY.
1. When coupled to a drying fan, delivering air flow in the range stated in
or on the heater rating plate.
2. When connected directly to a transition duct, delivering the air into the ventilation system of a grain
bin/store/dryer.
3. For drying whole agricultural grains.
4. When fitted with a temperature control system, including over temperature limiting thermostats, as
described in this manual.
5. With fuel specified on the rating plate.
6. With adequate air exhaust facility on the bin/store/dryer.
It shall NOT be used:
1. With any safety features by-passed.
2. For domestic or commercial heating.
3. In any potentially explosive area.
4. By an untrained person or any one less than 18 years old.
5. Where there is risk of flammable materials being drawn into or exposed to the flame.
6. If it has been modified in any way.
7. With covers or guards removed or loose.
8. Unless the commissioning sheet (in this manual) has been filled in and signed of by the
installing engineer.
In addition:
1. All electrical installation must be carried out by a qualified electrical engineer.
2. All gas installation must be carried out by a qualified gas engineer.
3. The entire installation shall meet the full requirements of all EU Directives, EU standards and local
codes and laws.
4. The heater shall never be lit manually.