![GSI Group 890-00584 Installation And Configuration Manual Download Page 26](http://html1.mh-extra.com/html/gsi-group/890-00584/890-00584_installation-and-configuration-manual_2275189026.webp)
NOTE:
Leave a clearance of at least 16 inches at the top of the enclosures to allow the cover to be
removed for maintenance.
6. Ensure the ventilation openings on the sides of the enclosures are not obstructed.
Installing and Connecting the Battery in the Battery Enclosure
1. Put battery terminals toward the top.
2. Align both Velcros in the Battery Box and then press on the battery to fasten it to the battery
enclosure.
3. Install the black wire (from printed circuit board J4) to the negative battery terminal.
4. Install the red wire (from printed circuit board J3) to the positive battery terminal.
5. Close the circuit of the main sector voltage to reactivate the controller.
Connecting the Siren
The siren is used as a visual and audio queue when an alert is active. The use of a siren is optional.
Before You Begin
NOTICE
The maximum voltage supplied to the siren is 12 VDC with a maximum current of 1
ampere.
NOTICE
The siren’s audio must not exceed 120 decibels.
NOTICE
The system must be connected to the battery if a siren is used.
1. Connect the wires from the siren to the SIREN terminals on the main board.
Make sure the positive wire is connected to the positive terminal of the siren.
2. If the siren’s impedance is too high, add a 1.5 ohm resistor (1/2 watt) in parallel with the siren, as
close as possible to the siren on the circuit.
3. If you are not using a siren, connect a 1.5 ohm resistor (1/2 watt) to the siren output or disable the
siren monitoring.
Connecting the Power Supply to a Power Source
Once the main enclosure and the battery enclosure are mounted to the wall and connected together, the
last step before configuration is to connect the equipment to a power source.
Before You Begin
26
895-00677
Agri Alert 128 Touch
Summary of Contents for 890-00584
Page 14: ...NOTES 14 895 00677 Agri Alert 128 Touch...
Page 20: ...NOTES 20 895 00677 Agri Alert 128 Touch...
Page 30: ...NOTES 30 895 00677 Agri Alert 128 Touch...
Page 38: ...NOTES 38 895 00677 Agri Alert 128 Touch...
Page 44: ...NOTES 44 895 00677 Agri Alert 128 Touch...
Page 64: ...Chapter 9 Configuring a 0 5 Volt Zone Type 64 895 00677 Agri Alert 128 Touch...
Page 66: ...NOTES 66 895 00677 Agri Alert 128 Touch...
Page 82: ...NOTES 82 895 00677 Agri Alert 128 Touch...
Page 88: ...NOTES 88 895 00677 Agri Alert 128 Touch...
Page 92: ...NOTES 92 895 00677 Agri Alert 128 Touch...
Page 96: ...NOTES 96 895 00677 Agri Alert 128 Touch...
Page 100: ...NOTES 100 895 00677 Agri Alert 128 Touch...
Page 102: ...NOTES 102 895 00677 Agri Alert 128 Touch...
Page 106: ...NOTES 106 895 00677 Agri Alert 128 Touch...
Page 107: ...F Wiring Diagram with Terminals 895 00677 Agri Alert 128 Touch 107...
Page 110: ...NOTES 110 895 00677 Agri Alert 128 Touch...
Page 118: ......