background image

USER MANUAL

GBP48V SERIES

Product manual of lithium iron

phosphate battery for communication

Version 1.0

JIANGSU GSO NEW ENERGY TECHNOLOGY CO.,LTD

Summary of Contents for GBP48V Series

Page 1: ...USER MANUAL GBP48V SERIES Product manual of lithium iron phosphate battery for communication Version 1 0 JIANGSU GSO NEW ENERGY TECHNOLOGY CO LTD...

Page 2: ...tion 3 4 1 Working mode 3 4 2 LED indicator description 3 4 3 Functional description 4 4 4 Power on Power off 6 4 5 Product picture and Data sheet 6 4 6 Performance test 8 V Communication description...

Page 3: ...lled in a ventilated and dry environment Considering that the battery adopts natural air cooling the battery should not be too close to the heat source to ensure the ambient temperature and maintenanc...

Page 4: ...strong compatibility can be seamlessly connected with UPS photovoltaic power generation and other main equipment various forms of communication interfaces CAN RS485 etc can be based on Customized acc...

Page 5: ...human computer interaction of the upper computer software The baud rate of the host computer is 9600 or19200 4 1 Working mode Charging mode When the BMS detects that the charger is connected and the...

Page 6: ...the battery voltage is higher than the total voltage overcharge protection setting value the BMS enters the overcharge protection state and the charging device cannot charge the battery When the tota...

Page 7: ...d on or the charging is released Temperature protection and recovery BMS has 6 temperature detection ports which implement protection measures by monitoring temperature changes Charging and dischargin...

Page 8: ...ll be activated and the LED indicator will flash in turn then it will enter the normal working state 2 Power off dormant When the BMS is in the standby or discharging state press this key for 3 second...

Page 9: ...ing current A 25 50 Max Constant charging current A 50 100 Standard discharging current A 25 50 Max Discharging current A 50 100 Temperature 30 60 Recommend 10 35 Allowable humidity range 0 85 RH Stor...

Page 10: ...BATTERY FOR COMMUNICATION 8 4 6 Performance test Nominal Capacity The battery pack is placed in a 25 environmental chamber 0 2C constant current and constant voltage to 54 65V 0 05C cut off put it as...

Page 11: ...ICATION 9 Rate charging The battery pack are charged at a constant current of 0 1C 0 2C 0 3C 0 5C and 1C to 54 75V in an environment of 25 Stop charging after the constant voltage reaches 0 05C and re...

Page 12: ...PRODUCT MANUAL OF LITHIUM IRON PHOSPHATE BATTERY FOR COMMUNICATION 10 Rate discharge...

Page 13: ...PRODUCT MANUAL OF LITHIUM IRON PHOSPHATE BATTERY FOR COMMUNICATION 11...

Page 14: ...days Storage performance place at room temperature In a normal temperature environment 100 SOC storage for 28 days test capacity retention and recovery rate Test for 5 groups batteries Storage perform...

Page 15: ...25 0 2C constant current charge to 53 25V constant voltage to 0 05C cut off after 30 minutes of storage 0 2C discharge Power to 42V cycle to 80 SOC cut off 25 1C constant current charge to 53 25V con...

Page 16: ...situation press the start button of the battery pack visually check whether the LED indicator is normal and then use the multimeter measures the voltage value of each battery pack in turn When the bat...

Page 17: ...hen battery packs are connected in parallel the DIP switch is used to distinguish different pack addresses The hardware address can be set by the DIP switch on the board Refer to the table below for t...

Page 18: ...PRODUCT MANUAL OF LITHIUM IRON PHOSPHATE BATTERY FOR COMMUNICATION 16 two pieces in parallel diagram Three pieces in parallel diagram PC Output PC Output...

Page 19: ...ion function for uploading battery packs and the CAN communication interface adopts the 8P8C network cable interface It can communicate with inverter or CAN TEST through CAN interface When the battery...

Page 20: ...ack is connectedin parallel use the DIP switch to distinguishdifferentpack addresses and the hardwareaddress can be set by the DIP switch on the board Stand alone address setting 0000 0000 Parallel ad...

Page 21: ...OFF OFF Pack1 2 OFF ON OFF OFF Pack2 3 ON ON OFF OFF Pack3 4 OFF OFF ON OFF Pack4 5 ON OFF ON OFF Pack5 6 OFF ON ON OFF Pack6 7 ON ON ON OFF Pack7 8 OFF OFF OFF ON Pack8 9 ON OFF OFF ON Pack9 10 OFF...

Page 22: ...in parallel 4 ON ON OFF OFF 4 in parallel 5 OFF OFF ON OFF 5 in parallel 6 ON OFF ON OFF 6 in parallel 7 OFF ON ON OFF 7 in parallel 8 ON ON ON OFF 8 in parallel 9 OFF OFF OFF ON 9 in parallel 10 ON...

Page 23: ...PRODUCT MANUAL OF LITHIUM IRON PHOSPHATE BATTERY FOR COMMUNICATION 21 Two piece in parallel diagram Three piece in parallel diagram Slave Host PC Slave Host PC...

Page 24: ...d to discharge the battery artificially every 6 months C If the battery is found to be bad the entire battery pack should be replaced in time D Try to avoid deep discharge of the battery The recommend...

Page 25: ...nty service does not cover damage caused by the following reasons Damage during the transportation of the equipment except for those transported by Jiangsu GSO New Energy Technology Co Ltd Damage caus...

Page 26: ...flammable materials such as packaging materials cartons cartons etc and a separate warehouse is recommended Where there are lithium batteries there must be some illegal regulations such as prohibiting...

Page 27: ...waste disposal unit for disposal B For bad batteries during the storage period after the battery is insulated to prevent accidental short circuit try to restore the original factory packaging to ensur...

Page 28: ...JIANGSU GSO NEW ENERGY TECHNOLOGY CO LTD ADD NO 142 NORTH JINSHAN ROAD YANGZHOU CITY JIANGSU PROVINCE P R C CHINA TEL 86 514 87520588 EMAIL INFO GSOPOWER COM WEBSITE WWW GSOPOWER COM...

Reviews: