Summary of Contents for TD-3140

Page 1: ...Part no Product name Spec Color Designer K 100 K 20 311 3140200 005 L148 W105mm 模造紙80P 黑 共28頁 騎馬釘 機器說明書 GRx Diagnostics 英文 Tsaiyi ...

Page 2: ...Owner s Manual Blood Pressure Monitor TD 3140 ...

Page 3: ......

Page 4: ...arefully Managing your blood pressure is simple with this device It s small enough to take with you anywhere and auto uploads all of your readings to the GRx BP smartphone App In addition this device will help you and your healthcare professional to keep your blood pressure under control and adjust your treatments plans as needed If you have further questions about this system please contact GRx D...

Page 5: ...is for reference only Always consult your doctor to have the results interpreted 5 Keep the equipment away from hot surfaces 6 Do NOT apply the cuff to areas other than the place directed 7 Use of this device in a dry environment especially if synthetic materials are present synthetic clothing carpets etc may cause damaging static discharges This may cause erroneous results 8 Do NOT use this devic...

Page 6: ... TEST 11 Before Measurement 11 Apply the Cuff Properly 11 Proper Measurement Position 12 HOW TO TEST YOUR BLOOD PRESSURE 13 Taking Measurement by the Device Itself 13 Taking Measurement with the GRx BP APP 14 MAINTENANCE 17 Battery 17 Caring for your meter 18 DETAILED INFORMATION 19 SYSTEM TROUBLESHOOTING 20 Error Messages on Meter 20 Troubleshooting 21 SYMBOL INFORMATION 22 SPECIFICATIONS 23 TABL...

Page 7: ... years and over for use in a home or clinical setting The device is not to be used for the diagnosis of hypertension abnormally high blood pressure or for testing on newborn babies Test Principle Blood pressure is measured non invasively at the arm based on oscillometric method This device is NOT able to take measurements in the presence of common arrhythmia irregular heartbeat such as atrial or v...

Page 8: ...7 Meter Overview Bluetooth Indicator Download test results with a Bluetooth connection Cuff immovable Display Screen Battery Compartment ON OFF Button Bluetooth Pairing Button 1 2 3 5 4 6 2 1 3 4 6 5 ...

Page 9: ... Screen Low Battery Symbol Pulse Rate Symbol Diastolic Pressure Value Systolic Pressure Value Units of Blood Pressure Systolic Pressure Symbol Diastolic Pressure Symbol Pulse Rate 1 2 3 6 4 7 5 8 4 3 2 1 5 6 7 8 ...

Page 10: ...sion System Requirement For iOS and Android devices please find the GRx BP APP on the App store and Google Play respectively Installing GRx BP App is available on the App Store Play Store for free download Connect your mobile device to the internet to download the GRx BP App and then install on your mobile device Updating When new features are added to the GRx BP App the App Store will notify you ...

Page 11: ... APP with the device the Bluetooth function of meter shall be on before transmitting data to your app Bluetooth indicator on the meter BLUETOOTH INDICATOR STATUS Flashing Blue The Bluetooth function is on and waiting for connection Solid Blue The Bluetooth connection is established NOTE While the meter is in transmission mode it is unable to measure blood pressure Make sure your device supports Bl...

Page 12: ... the records for your doctor as reference Blood pressure naturally varies between each arm Always measure your blood pressure on the same arm Apply the Cuff Properly 1 Stretch your arm in front of you with your palm facing up Slide and place the cuff onto your arm the arrow should point towards the forearm 2 Wrap and tighten the cuff above your elbow The red line on the edge of the cuff should be ...

Page 13: ...lat surface Relax your hand with the palm facing up 3 Remain still and do not talk or move during the measurement NOTE The blood pressure monitor is fixed onto the cuff Do NOT remove the cuff or change to another different sized cuff WARNING If the cuff is relatively lower higher than the heart the obtained blood pressure value could be higher lower than the actual value A 15 cm 5 9 difference in ...

Page 14: ...s or the measured result will be stored in the meterʼs memory with incorrect date and time If you tap ON OFF Button during measurement the meter will turn off HOW TO TEST YOUR BLOOD PRESSURE Taking Measurement with the Device Itself Always apply the pressure cuff before turning on the meter 1 Tap ON OFF Button All the LCD symbols will appear with a long beeping sound Then the cuff will begin to in...

Page 15: ...ly the pressure cuff and then tap in green on the screen of GRx BP App All the LCD symbols will appear with a long beeping sound on the device monitor The cuff will begin to inflate automatically until it reaches the working pressure The in green will turn into in red on the App screen during measurement If you want to stop the measurement press in red to terminate it and the meter will switch off...

Page 16: ...ill also see a curve diagram below the pulse rate The diagram is only available when the measurement is initiated via the app rather than by the meter s ON OFF button Tap on the diagram to view more information This curve and its contents are for reference only Please consult medical professionals for further diagnoses 1 Press the Bluetooth button The PCL icon will appear on the meter display indi...

Page 17: ...nder the pulse rate a pop up window will appear to display the predicted analysis of your average result Press the upper right icon x to close the pop up window The in green will turn into in red on the App screen during measurement If you want to stop the measurement press in red to terminate it and the meter will switch off 4 After the first measurement is complete the device and GRx BP App will...

Page 18: ...curate but it is time to change the batteries 2 The symbol appears with E b The power is not enough to do a test You must change the batteries immediately MAINTENANCE Battery Your meter comes with four 4 1 5 V AAA size alkaline batteries Low Battery Signal The meter will display either of the two messages below to alert you when the meter power is getting low Replacing the Battery To replace the b...

Page 19: ...clean the meter Do NOT wash or iron the pressure cuff Meter Storage Storage condition 25 C to 70 C 13 F to 158 F 10 to 95 relative humidity Always store or transport the meter in its original storage case Avoid dropping or heavy impact Avoid direct sunlight and high humidity Replacing the batteries does not affect the test results stored in memory After battery replacement please pair the meter wi...

Page 20: ...ing to the blood vessels Rising blood pressure accelerates hardening of the arteries and the body becomes more susceptible to apoplexy and coronary infarction The recommended blood pressure range is as below Classification Systolic Pressure mmHg Diastolic Pressure mmHg Hypotension 2 90 60 Normal 3 120 80 Pre hypertension 3 120 139 80 89 Stage 1 Hypertension 3 140 159 90 99 Stage 2 Hypertension 3 1...

Page 21: ...ror Refit cuff tightly and correctly Relax and repeat the measurement If error still persists contact GRx Diagnostics for help E A E E Problems with the meter Review the instructions and repeat the test If the meter still does not work please contact GRx Diagnostics for help E b Battery is too low Replace with new batteries NOTE The information here is only displayed on the meter screen ...

Page 22: ...nutes before repeating measurement 3 If blood pressure is higher lower than user s average measurement POSSIBLE CAUSE WHAT TO DO May not be in correct position while measuring Blood pressure naturally varies from time to time Blood pressure naturally varies from time to time Keep in mind for next measurement 4 If the cuff inflates again while measuring POSSIBLE CAUSE WHAT TO DO Cuff is not fastene...

Page 23: ...tructions for use Type BF Equipment Manufacturer Temperature limitation Serial number Do not dispose of as household waste Ingress protecting rating CE mark Caution consult accompanying documents Humidity limitation Authorised representative in the European Community ...

Page 24: ... to 1060 hPa Meter Storage Condition 25 C to 70 C 13 F to 158 F 10 to 95 RH Blood Pressure Measurement Performance Systolic Measurement Range 60 mmHg 255 mmHg Diastolic Measurement Range 30 mmHg 195 mmHg Pulse Rate Measurement Range 40 to 199 beats minute Accuracy of Pressure 3 mmHg or 2 of reading Accuracy of Pulse Rate 4 of reading Measurement Unit Fixed mmHg for meter either mmHg or Kpa for App...

Page 25: ... to Standards IEC60601 1 General requirement for safety IEC60601 1 2 Requirements for EMC IP22 Object size protected against 12 5 mm Fingers or similar objects Protected against Dripping water when tilted up to 15 ...

Page 26: ...NOTE ...

Page 27: ...NOTE ...

Page 28: ......

Page 29: ...Rd Wugu Dist 24888 New Taipei City Taiwan www taidoc com MedNet GmbH Borkstraβe 10 48163 Münster Germany Distributed by GRx Diagnostics 4 Wintonlea Monument Way West Woking Surrey GU21 5EN UK Website www grxdiagnostics co uk Customer careline 01483 755133 ...