Grundfos Vaccuperm VGA-111 Installation And Operating Instructions Manual Download Page 6

English (GB)

6

2. Introduction

2.1 Correct usage

The VGA-111 vacuum regulator is exclusively designed for 
reducing the overpressure from the chlorine tank side to the 
negative pressure on the vacuum side.

2.2 Inappropriate usage

Operational safety is only guaranteed, if the product is used 
correctly. All operating methods conflicting with correct usage are 
not permitted, and lead to the expiry of all liability claims.

2.3 Qualification of the users

Based on his professional training and experience, the user must 
have a good knowledge of the operation of chlorine gas dosing 
systems. He must be so familiar with the relevant laws and 
regulations governing safety in the workplace and accident 
prevention, and with the recognised standards of good practice, 
that he is able to judge the safe working condition of a chlorine 
gas dosing system.
The user is responsible for operation and monitoring of the 
product at the installation site.
The responsibilities of the user:
• Read this manual before operating the product.
• Be trained by qualified Grundfos personnel in the operation of 

the product.

• Observe the relevant regulations governing safety in the 

workplace and accident prevention.

• Wear appropriate protective clothing in accordance with 

national regulations for the prevention of accidents when 
operating the system and handling chemicals.

2.4 Responsibilities of the operator

The operator of the product is responsible for the following:
• Ensure that this manual is kept clearly accessible in the 

immediate vicinity of the system for the entire service life.

• Meet the installation requirements specified by the 

manufacturer (environmental conditions, required water 
connections and fittings, electrical connection, protective pipe 
for dosing line if necessary, audible or optical warning device if 
necessary).

• Ensure that water lines and armatures are regularly checked, 

serviced and maintained.

• Obtain official approval for storing chemicals, if necessary.
• Train users in the operation of the system.
• Ensure that the regulations for the prevention of accidents are 

observed in the installation site.

• Provide all users and service personnel with protective 

clothing (e.g. face mask, gloves, protective apron) in 
accordance with the national regulations.

2.5 Maintenance and service personnel

The product may only be maintained and serviced by personnel 
authorised by Grundfos.

Warning
Unauthorised structural modifications to the product 
may result in serious damage to equipment and 
personal injury.
It is forbidden to open, modify, bridge, remove, 
bypass or disable components, especially safety 
equipment.

Summary of Contents for Vaccuperm VGA-111

Page 1: ...Vaccuperm VGA 111 Vacuum regulator Installation and operating instructions GRUNDFOS INSTRUCTIONS Other languages http net grundfos com qr i 95714202...

Page 2: ...rst aid in case of accidents 3 1 5 Handling chlorine containers 4 1 6 Chlorine rooms 5 2 Introduction 6 2 1 Correct usage 6 2 2 Inappropriate usage 6 2 3 Qualification of the users 6 2 4 Responsibilit...

Page 3: ...ive equipment Outside the chlorine rooms Well visible Easily available at any time Protected from dust and moisture 1 4 First aid in case of accidents 1 4 1 First aid after inhaling chlorine 1 Keep ca...

Page 4: ...atures over 50 C Transport containers only with valve protection nut and protective cap 1 5 4 Valid regulations In Germany the following regulations apply Regulations for accident prevention Chlorinat...

Page 5: ...ust have a run off with air trap Operation must be possible manually from outside the chlorine rooms A chlorine gas warning system must be installed with optical and acoustical alarm device with conne...

Page 6: ...ate protective clothing in accordance with national regulations for the prevention of accidents when operating the system and handling chemicals 2 4 Responsibilities of the operator The operator of th...

Page 7: ...n B Directly on the cylinder W Wall mounting C Header line BC Directly on the cylinder header line Connection 1 G 1 2 G 3 4 3 U S yoke 4 Copper pipe 6 8 mm Inlet valve B Basic S Short L Long 230 240 V...

Page 8: ...cal indication Weight Approx 2 4 kg according to the execution of the pressure connection Pressure gauge 0 16 bar with without limit contact for setting the minimum admission pressure Short inlet valv...

Page 9: ...t 34 05 C Density gas 3 214 g l at 0 C 1 bar 1 litre of liquid chlorine at 0 C is equivalent to 457 litres 0 457 m3 of chlorine gas 1 kg of liquid chlorine at 0 C is equivalent to 311 litres 0 311 m3...

Page 10: ...ich reduces the overpressure from the chlorine tank side to the negative pressure on the vacuum side The valve at the vacuum regulator opens when after switching on the injector a sufficient vacuum ha...

Page 11: ...ap are available for more safety Dosing regulator C The chlorine gas volume flow is adjusted with the dosing regulator This can be effected manually or automatically via motor control Injector D Injec...

Page 12: ...tions Max length m of the vacuum lines between vacuum regulator and dosing regulator Dosing quantity g h 40 100 250 500 1000 2000 4000 0 DN 8 DN 8 DN 8 DN 8 DN 8 DN 8 DN 10 10 DN 8 DN 8 DN 8 DN 8 DN 8...

Page 13: ...or 2 Overpressure line to the adsorption filter 3 Vacuum line from the vacuum regulator 4 Vacuum line to the injector Warning Replace the gaskets of the pressure connection at any change of container...

Page 14: ...se all chlorine container valves 2 Open container connection valves and all shut off valves up to the chlorine gas dosing system 3 Open the connection valve of the nitrogen cylinder 4 Slowly open the...

Page 15: ...the valves of full or empty chlorine containers with closing nut marked chlorine or Cl2 and gasket Stuck valves Stuck valves can be loosened by wrapping a cloth with warm water around the valve If thi...

Page 16: ...um regulator onto the chlorine container 13 Check the tightness as described in section 6 1 Checking the tightness 14 Re start the system 7 3 Switching off the chlorine gas dosing system 7 3 1 Emergen...

Page 17: ...tainer damaged Use another chlorine container d Pressure connection loose Tighten the pressure connection e Sealing surface at the pressure connection of the vacuum regulator damaged Call the service...

Page 18: ...kich PT Declara o de conformidade UE A Grundfos declara sob sua nica responsabilidade que os produtos VGA 111 VGA 113 VGA 117 VGA 146 VGB 103 VGS 141 VGS 143 VGS 145 VGS 147 VGS 148 aos quais diz resp...

Page 19: ...19 Declaration of conformity EAC 2 Vaccuperm 004 2011 010 2011 020 2011 TC RU C DK 30 01214 17 12 2019 153032 1 Vaccuperm 032 2013 TC N RU DK 30 05343 08 10 2020 1 2016 143581 188...

Page 20: ...20...

Page 21: ...ia S r l Via Gran Sasso 4 I 20060 Truccazzano Milano Tel 39 02 95838112 Telefax 39 02 95309290 95838461 Japan GRUNDFOS Pumps K K 1 2 3 Shin Miyakoda Kita ku Hamamatsu 431 2103 Japan Phone 81 53 428 47...

Page 22: ...splayed in this material including but not limited to Grundfos the Grundfos logo and be think innovate are registered trademarks owned by The Grundfos Group All rights reserved 2019 Grundfos Holding A...

Reviews: