Page 10

Power: 120 ±10% 50/60 Hz 240 VA

Demand: 20-30 V (ac) 0.1 VA

Var. Speed: 120 V (ac) 1.8 A 1/12 hp

Relay: 30 V (ac), 2.5 A pilot duty

Grundfos GVSPD PCB layout

Part Nº:  1008-02

Version: 4

The  information  and  drawings  contained  herein  are  the  sole
property  of  tekmar  Control  Systems  Ltd.  and  shall  not  be
disclosed to 3rd parties without express written consent of tekmar.

tekmar Control Systems Ltd.

Checked by: SS

Scale:  Full size

Date: Jan. 17, 2007

Notes:

• Printing on PCB is white.

• Label affixed to transformer top showing tekmar no. (1008-02), Grundfos part no. 

(599395), Date code, and Lot no.

MOV

100µ

0.1µF

R

Signal wires must  be min. 300V rating

Sup

Com

Ret / I

Com(-)

Os / V

Boil

Boil

Dem

Dem

tN4

Fuse

Transformer 1 VA

115 V : 18 V

100

ȝ

H 6 A inductor

Pot

0.1

ȝ

F

250V

R

Class 2 

only

Off

On

A B C D

1008-02 599395

May 2006 12345

Made in Canada

Meets Class B: Canadian ICES Fcc Part 15

Use copper  conductors only

Changes V3 to V4:

1. Adjusted relay rating to show new relay 

rating of 2.5 A pilot duty

Grundfos Variable Speed Control Board

Summary of Contents for UP15-42F

Page 1: ...nd Operation 1 2 3 4 5 6 7 Electrical Pump Installation Operational Limits General Features Shipment Inspection Settings Quick Reference GRUNDFOS INSTRUCTIONS Pumps Incorporating the VS Variable Speed...

Page 2: ...roper installation and operation of this control could result in damage to the equipment and possibly even personal injury It is your responsibility to ensure that this control is safely installed acc...

Page 3: ...and safety devices must be added Offset dial provides fine tuning for input signal Manual dial provides manual speed control Range of signal is selected through Dip Switch A Type of signal used is se...

Page 4: ...re intended for use with water or a 50 50 mixture by weight of propylene glycol UP15 42F VS 115V 60 Hz Maximum Fluid Temperature 205 F 96 C Maximum Ambient 107 F 42 C with control module vertical Fig...

Page 5: ...freely Remove the large screw in the middle of the nameplate insert a small flat blade screwdriver into the end of the shaft and turn gently If the shaft does not turn easily repeat the disas sembly...

Page 6: ...ge remaining air from the bearing chamber This is especially important when installing the pump during the off season 5 Electrical Warning All electrical work should be performed by a qualified electr...

Page 7: ...he wires Current Speed Control Signal Connections Connect the current signal wires to terminals Com and Ret I Fig 3 Test the Speed Control Signal Wiring Make sure exposed wires and bare terminals are...

Page 8: ...f the pump will have a range from minimum speed 15 to a maximum speed 100 Dip Switch D speed control external speed control maximum dial When dip switch D is in the ON position an external V dc mA sig...

Page 9: ...al allows the speed of the pump to be manually adjusted and set by the user The speed of the pump may be manually adjusted anywhere from min to 100 but once set remains fixed at that speed The min pos...

Page 10: ...10V 4 20mA min speed off speedcontrol manual dial speedcontrol external A B C D 7 Quick Reference Setting Dip Switches Figure 7A DipSwitches Dip switch settings POSITION Feature Explanation Dip switc...

Page 11: ...s must be min 300V rating Sup Com Ret I Com Os V Boil Boil Dem Dem tN4 Fuse Transformer 1 VA 115 V 18 V 100 H 6 A inductor Pot 0 1 F 250V R Class 2 only Off On A B C D 1008 02 599395 May 2006 12345 Ma...

Page 12: ...te and sup porting installation data Unless otherwise provided the distributor or dealer will contact the GRUNDFOS factory or authorized service station for instructions Any defective product to be re...

Reviews: