4. Installation

4.1 Position of the terminal box

Proper installation of the pump will have the 
terminal box located to one side of the pump or 
the other, with the conduit entry down. See fig. 

1

.

Fig. 1

Recommended terminal box 
orientation

4.2 How to change the terminal box 

position

How to change terminal box position:
1. Remove the four (4) hex socket head screws 

(4 or 5 mm wrench) while supporting the 
stator (motor).

2. Carefully separate the stator from the pump 

housing and rotate it to the correct terminal 
box orientation.

3. Replace the hex socket head screws and 

tighten diagonally and evenly (7 ft.-
lb.torque).

4. Check that the impeller turns freely. If the 

impeller does not turn easily, repeat the 
disassembly/reassembly process.

4.2.1 Pump mounting: for indoor use

When making pipe connections, be sure to 
follow the pipe manufacturer's recommendations 
and all code requirements for piping material.
Arrows on the side or bottom of the pump 
housing indicate direction of flow through the 
pump. Grundfos circulator pumps can be 
installed in both vertical and horizontal lines. 
The pump must be installed with the motor shaft 
positioned horizontally.
Under no circumstances should the pump be 
installed with the shaft vertical or where the 
shaft falls below the horizontal plane.
See fig. 

2

.

Fig. 2

Acceptable pump mounting 
positions

We recommend that isolating valves be installed 
on each side of the pump. If possible, do not 
install elbows, branch tees, and similar fittings 
just before or after the pump. Provide support to 
the pump or adjacent plumbing to reduce 
thermal and mechanical stress on the pump.

4.3 Installation requirements

1. Thoroughly clean and flush the system prior 

to pump installation.

2. Do not install the pump at the lowest point of 

the system where dirt and sediment naturally 
collect.

3. Install an air vent at the high point(s) of the 

system to remove accumulated air.

4. Ensure that water does not enter the 

terminal box during the installation process.

5. Open system: Install the pump in the supply 

line; the suction side of the pump should be 
flooded with water. Ensure that the static 
head requirement from Table B is achieved.

6. Closed system: Install a safety relief valve to 

protect against temperature and pressure 
build-up.

7. If the water contains suspended particles, we 

recommend that a strainer and/or filter be 
installed and cleaned regularly.

4.3.1 Check valve removal

1. Use needle-nose pliers to remove check 

valve from pump housing.

2. Check to make sure no part of the valve 

remains in the pump housing.

3. Apply the enclosed round "Check Valve 

Removed" label over the check mark symbol 
located on the nameplate of the pump.

T

M

05

 55

63

 38

12

WARNING

If the terminal box position needs to 
be changed, ensure that the power 
supply is turned off and close the 
isolating valves before removing the 
hex socket head screws.

TM

05

 55

64

 38

12

Do not start the pump until the system 
has been filled.

Acceptable

Not acceptable

Summary of Contents for UP 15-100F

Page 1: ...GRUNDFOS INSTRUCTIONS UP Series circulators Installation and operating instructions UP15 and UP26 Stainless and Bronze ...

Page 2: ...instructions To obtain service under this warranty the defective product must be returned to the distributor or dealer of GRUNDFOS products from which it was purchased together with proof of purchase and installation date failure date and supporting installation data Unless otherwise provided the distributor or dealer will contact the GRUNDFOS factory or authorized service station for instructions...

Page 3: ... by volume solution of ethylene or propylene glycol and water can be used however a decrease in pump performance may result due to an increase in the viscosity of the solution Check with manufacturer for information regarding suitability of pumping other liquids Closed systems Model UP S 15 26 43 and 50 series pumps with cast iron pump housings are designed to pump water compatible with their cast...

Page 4: ...tank pool etc Table A Maximum water temperature Ambient temperature 104 F 40 C 120 F 48 C 140 F 60 C 160 F 71 C 175 F 79 C Water temperature All UP 230 F 110 C 220 F 104 C 210 F 98 C 190 F 87 C 175 F 79 C Exceptions below UPS 15 35 165 F 73 C 140 F 60 C UP 15 100F 205 F 96 C 195 F 90 C 185 F 85 C 175 F 79 C UP 26 120U 205 F 96 C 195 F 90 C 185 F 85 C 175 F 79 C UP 26 116 150 F 65 C 140 F 60 C Tabl...

Page 5: ...es be installed on each side of the pump If possible do not install elbows branch tees and similar fittings just before or after the pump Provide support to the pump or adjacent plumbing to reduce thermal and mechanical stress on the pump 4 3 Installation requirements 1 Thoroughly clean and flush the system prior to pump installation 2 Do not install the pump at the lowest point of the system wher...

Page 6: ... pumps 5 1 2 Multi speed pump wiring 1 Insert black conductor into terminal L position 2 Insert white conductor into terminal N position 3 Insert grounding conductor into terminal position Fig 4 Wiring diagram for 115 V and 230 V multi speed pumps UP S 15 capacitor wire position 4 8 UP S 26 43 50 capacitor wire position 2 4 WARNING All electrical work should be performed by a qualified electrician...

Page 7: ...e end of the shaft and gently turn until the shaft moves freely Replace and tighten the plug Open the isolating valves and wait 2 to 3 minutes for the system pressure to equalize before starting the pump 9 Disposal This product or parts of it must be disposed of in an environmentally sound way 1 Use the public or private waste collection service 2 If this is not possible contact the nearest Grundf...

Page 8: ... O Box 16768 Jebel Ali Free Zone Dubai Phone 971 4 8815 166 Fax 971 4 8815 136 www grundfos uae GRUNDFOS Canada 2941 Brighton Road Oakville Ontario L6H 6C9 Canada Phone 1 905 829 9533 Telefax 1 905 829 9512 www grundfos ca GRUNDFOS México Boulevard TLC No 15 Parque Industrial Stiva Aeropuerto C P 66600 Apodaca N L México Phone 011 52 81 8144 4000 Fax 011 52 81 8144 4010 www grundfos mx ...

Page 9: ...ECM 1202189 www grundfos com The name Grundfos the Grundfos logo and be think innovate are registered trademarks owned by Grundfos Holding A S or Grundfos A S Denmark All rights reserved worldwide Copyright Grundfos Holding A S ...

Reviews: