Installation and operating instructions

Original installation and operating 
instructions

These installation and operating instructions 
describe Grundfos ALPHA2 26-99 circulator 
pumps. 
Sections 1-4 give the information necessary to 
be able to unpack, install and start up the 
product in a safe way.
Sections 5-9 give important information about 
the product, as well as information on service, 
fault finding and disposal of the product.

CONTENTS

Page

1. Limited warranty

Products manufactured by Grundfos Pumps 
Corporation (Grundfos) are warranted to the 
original user only to be free of defects in 
material and workmanship for a period of 30 
months from date of installation, but not more 
than 36 months from date of manufacture. 
Grundfos' liability under this warranty shall be 
limited to repairing or replacing at Grundfos' 
option, without charge, F.O.B. Grundfos' factory 
or authorized service station, any product of 
Grundfos manufacture. Grundfos will not be 
liable for any costs of removal, installation, 
transportation, or any other charges that may 
arise in connection with a warranty claim.
Products which are sold, but not manufactured 
by Grundfos, are subject to the warranty 
provided by the manufacturer of said products 
and not by Grundfos' warranty.
Grundfos will not be liable for damage or wear to 
products caused by abnormal operating 
conditions, accident, abuse, misuse, 
unauthorized alteration or repair, or if the 
product was not installed in accordance with 
Grundfos' printed installation and operating 
instructions and accepted codes of good 
practice. The warranty does not cover normal 
wear and tear.
To obtain service under this warranty, the 
defective product must be returned to the 
distributor or dealer of Grundfos' products from 
which it was purchased together with proof of 
purchase and installation date, failure date and 
supporting installation data. Unless otherwise 
provided, the distributor or dealer will contact 
Grundfos or an authorized service station for 
instructions. Any defective product to be 
returned to Grundfos or a service station must 
be sent freight prepaid; documentation 
supporting the warranty claim and/or a Return 
Material Authorization must be included if so 
instructed.
Grundfos will not be liable for any incidental or 
consequential damages, losses, or expenses 
arising from installation, use, or any other 
causes. There are no express or implied 
warranties, including merchantability or fitness 

1.

Limited warranty

2

2.

General information

3

2.1 Hazard statements

3

2.2 Notes

3

3.

Installation

3

3.1 Changing the pump head position

4

3.2 Insulating the pump housing

5

3.3 Electrical installation

5

4.

Starting up the product

7

5.

Product introduction

8

5.1 Product description

8

5.2 Applications

8

5.3 Pumped liquids

8

5.4 Identification

9

5.5 Approvals

9

5.6 Performance curves

10

6.

Control functions

11

6.1 Internal control principles

11

6.2 External control principles

11

6.3 User interface (AUTO version)

13

7.

Fault finding the product

14

8.

Technical data

15

8.1 Approval codes

15

8.2 Operating conditions

15

9.

Disposing of the product

15

Read this document before installing 
the product. Installation and operation 
must comply with local regulations 
and accepted codes of good practice.

Children shall not play with the 
appliance. Cleaning and user 
maintenance shall not be made by 
children.

Successful operation depends on 
careful attention to the procedures 
described in this manual. Keep this 
manual for future use.

Summary of Contents for TM07 2122 2818

Page 1: ...GRUNDFOS INSTRUCTIONS ALPHA 26 99 Installation and operating instructions...

Page 2: ...service under this warranty the defective product must be returned to the distributor or dealer of Grundfos products from which it was purchased together with proof of purchase and installation date f...

Page 3: ...ates a hazardous situation which if not avoided will result in death or serious personal injury WARNING Indicates a hazardous situation which if not avoided could result in death or serious personal i...

Page 4: ...s Fig 1 Control box positions DANGER Electric shock Death or serious personal injury Switch off the power supply before starting any work on the product Make sure that the power supply cannot be accid...

Page 5: ...al of the relay is able to handle higher inrush currents We recommend to use special inrush relays with silver tin oxide AgSnO contacts Leakage current The pump mains filter causes a leakage current t...

Page 6: ...injury Switch off the power supply before starting any work on the product Make sure that the power supply cannot be accidentally switched on WARNING Electric shock Death or serious personal injury Th...

Page 7: ...must be connected to an external main switch with a minimum contact gap of 0 12 inches 3 mm in all poles Grounding or neutralization must be used for protection against indirect contact WARNING Electr...

Page 8: ...Technical data The pump is suitable for the following liquids Clean thin non aggressive and non explosive liquids without solid particles or fibers If the pump is installed in a heating system the wa...

Page 9: ...Voltage V 3 Frequency Hz 4 Approval mark UL 5 Input power P1 W at maximum and minimum performance 6 Rated current A at maximum and minimum performance 7 Speed 8 Enclosure class 9 Product number 10 Pr...

Page 10: ...0 2 4 6 8 10 12 14 16 18 20 22 24 26 28 Q m h 0 0 0 5 1 0 0 5 2 0 2 5 3 0 3 5 4 0 4 5 5 0 5 5 6 0 6 5 7 0 Proportional pressure 3 Proportional pressure 2 Proportional pressure 1 Proportional pressure...

Page 11: ...10 VDC ALPHA1 26 99 circulators are externally speed controlled by an analog 0 10 V DC signal The pump requires a 0 10 V signal on the signal port to control the speed of the pump The pump will run at...

Page 12: ...d as cable break Rating Value Rated input voltage high level UIH 4 24 V Rated input voltage low level UIL 1 V High level input current IIH 10 mA PWM frequency output open collector f 75 Hz 5 Accuracy...

Page 13: ...as already been selected Start at the actual setting Press the button for two seconds The pump enters setting mode and the LED starts flashing Each time you press the button the setting changes LEDs 1...

Page 14: ...uit breaker d Power supply failure Check that the power supply falls within the specified range Normal power supply a The controller has switched off Check the controller and its settings b The pump i...

Page 15: ...r the pump surface Storage temperature Maximum 158 F 70 C Liquid temperature Maximum continuously 203 F 95 C Minimum 14 F 10 C Inrush current Measured on a flicker network according to IEC 61000 3 3 1...