17
7. Additional technical data
8. Disposal
This product or part of it must be disposed of
in an environmentally sound way; please use
the public or private waste collection service.
Supply voltage:
/-10 %, 60Hz
1 x 208 - 230V +/-10 %, 60Hz
Motor protection:
Thermally protected
Enclosure class:
CSA Type 2
Insulation class:
H
Max. discharge
press.:
145 psi (10 bar)
Max. sound press.
level:
30 dB(A)
Water hardness:
14 dH
Open systems
(domestic, potable hot water)
Fluid
Ambient
Min.
36 °F (2 °C)
33 °F (1 °C)
Max.
< 149 °F (65 °C)
100 °F (38°C)
In domestic hot-water systems,
it is recommended to keep the
liquid temperature below +149 °F
(+65 °C) to eliminate the risk of lime
precipitation.
Closed systems
(non-potable heating or cooling airless fluid)
XL pump
models
Fluid
Ambient
Min.
All
36 °F
(2 °C)
33 °F
(1 °C)
Max.
UPS 26-150
230 °F
(110 °C)
100 °F
(38°C)
UPS 43-100
230 °F
(110 °C)
100 °F
(38°C)
UPS 50-60
212 °F
(100 °C)
100 °F
(38°C)
Water and glycol mix
Max.
50 % glycol @ 15 °F (-9 5 °C) fluid
(Hydraulic performance change can be expected.)
Caution