3
English (US)
English (US)
Installation and operating instructions
Original installation and operating instructions.
CONTENTS
Page
1. Limited warranty
Products manufactured by GRUNDFOS PUMPS CORPORATION
(Grundfos) are warranted to the original user only to be free of
defects in material and workmanship for a period of 24 months
from date of installation, but not more than 30 months from date
of manufacture. Grundfos' liability under this warranty shall be
limited to repairing or replacing at Grundfos' option, without
charge, F.O.B. Grundfos' factory or authorized service station,
any product of Grundfos' manufacture. Grundfos will not be liable
for any costs of removal, installation, transportation, or any other
charges which may arise in connection with a warranty claim.
Products which are sold but not manufactured by Grundfos are
subject to the warranty provided by the manufacturer of said
products and not by Grundfos' warranty. Grundfos will not be
liable for damage or wear to products caused by abnormal
operating conditions, accident, abuse, misuse, unauthorized
alteration or repair, or if the product was not installed in
accordance with Grundfos' printed installation and operating
instructions.
To obtain service under this warranty, the defective product must
be returned to the distributor or dealer of Grundfos' products from
which it was purchased together with proof of purchase and
installation date, failure date, and supporting installation data.
Unless otherwise provided, the distributor or dealer will contact
Grundfos or an authorized service station for instructions. Any
defective product to be returned to Grundfos or a service station
must be sent freight prepaid; documentation supporting the
warranty claim and/or a Return Material Authorization must be
included if so instructed.
GRUNDFOS WILL NOT BE LIABLE FOR ANY INCIDENTAL OR
CONSEQUENTIAL DAMAGES, LOSSES, OR EXPENSES
ARISING FROM INSTALLATION, USE, OR ANY OTHER
CAUSES. THERE ARE NO EXPRESS OR IMPLIED
WARRANTIES, INCLUDING MERCHANTABILITY OR FITNESS
FOR A PARTICULAR PURPOSE, WHICH EXTEND BEYOND
THOSE WARRANTIES DESCRIBED OR REFERRED TO
ABOVE.
Some jurisdictions do not allow the exclusion or limitation of
incidental or consequential damages and some jurisdictions do
not allow limit actions on how long implied warranties may last.
Therefore, the above limitations or exclusions may not apply to
you. This warranty gives you specific legal rights and you may
also have other rights which vary from jurisdiction to jurisdiction.
1.
Limited warranty
3
2.
Symbols used in this document
4
3.
General information
4
4.
General description
4
4.1
Pumps without factory-fitted sensor
4
4.2
Pumps with pressure sensor
4
4.3
Settings
4
5.
Mechanical installation
4
5.1
Motor cooling
4
5.2
Outdoor installation
4
6.
Electrical connection
4
6.1
Single-phase pumps
5
6.2
Three-phase pumps, 1 - 10 Hp
6
6.3
Three-phase pumps, 15 - 30 Hp
9
6.4
Signal cables
11
6.5
E-pump electrical connections
11
6.6
Bus connection cable
12
7.
Modes
12
7.1
Overview of modes
12
7.2
Operating mode
12
7.3
Control mode
12
8.
Setting up the pump
13
8.1
Factory setting
13
9.
Setting by means of control panel
13
9.1
Setting of operating mode
13
9.2
Setpoint setting
13
10.
Setting by means of R100
14
10.1 Menu OPERATION
16
10.2 Menu STATUS
17
10.3 Menu INSTALLATION
18
10.4 Typical display settings for constant pressure E-pumps 24
10.5 Typical display settings for analog input E-pumps
25
11.
Setting by means of PC Tool E-products
26
12.
Priority of settings
26
13.
External forced-control signals
26
13.1 Start/stop input
26
13.2 Digital input
26
14.
External setpoint signal
27
15.
Bus signal
27
16.
Other bus standards
27
17.
Indicator lights and signal relay
28
18.
Insulation resistance
30
19.
Emergency operation (only 15 - 30 Hp)
30
20.
Maintenance and service
31
20.1 Cleaning of the motor
31
20.2 Relubrication of motor bearings
31
20.3 Replacement of motor bearings
31
20.4 Replacement of varistor (only 15 - 30 Hp)
31
20.5 Service parts and service kits
31
21.
Technical data - single-phase pumps
31
21.1 Supply voltage
31
21.2 Overload protection
31
21.3 Leakage current
31
21.4 Inputs/outputs
31
22.
Technical data - three-phase pumps, 1 - 10 Hp
32
22.1 Supply voltage
32
22.2 Overload protection
32
22.3 Leakage current
32
22.4 Inputs/output
32
23.
Technical data - three-phase pumps, 15 - 30 Hp
33
23.1 Supply voltage
33
23.2 Overload protection
33
23.3 Leakage current
33
23.4 Inputs/output
33
23.5 Other technical data
33
24.
Disposal
34
DBP-1 - GRUNDFOS PUMP CRE - 99392005
Summary of Contents for SPKE Series