6

Fig. 5

If the pump is installed horizontally, e.g. in a tank, it is recom-
mended to fit it in a flow sleeve. 

3.2.1 Motors suitable for horizontal installation

Note: During operation, the suction interconnector of the pump 
must always be completely submerged in the liquid. 

In special conditions, it may be necessary to submerge the pump 
even deeper, depending on the operating conditions of the actual 
pump and the NPSH value.

Note: If the pump is used for pumping hot liquids (40° to 60°C), 
care should be taken to ensure that persons cannot come into 
contact with the pump and the installation, e.g. by installing a 
guard.

3.3 Diameter of pump/motor 

The maximum diameter of the pump/motor is as shown in the 
table on page 109. 

It is recommended to check the borehole with an inside calliper to 
ensure unobstructed passage. 

3.4 Liquid temperatures/cooling 

The maximum liquid temperature and the minimum liquid velocity 
over the motor appear from the following table. 

It is recommended to install the motor above the well screen in 
order to achieve proper motor cooling. 

Note: In cases where the stated liquid velocity cannot be 
achieved, a flow sleeve must be installed. 

If there is a risk of sediment build-up, such as sand, around the 
motor, a flow sleeve should be used in order to ensure proper 
cooling of the motor. 

3.4.1 Maximum liquid temperature 

Out of consideration for the rubber parts in pump and motor, the 
liquid temperature must not exceed 40°C (~105°F). See also the 
following table. 

The pump can operate at liquid temperatures between 40°C and 
60°C (~105°F and 140°F) provided that all rubber parts are 
replaced every third year.

Note: By free convection is meant that the borehole diameter is 
at least 2" larger than the diameter of the submersible motor. 

Other motor makes: See motor specifications. 

4. Electrical connection 

4.1 General 

The electrical connection should be carried out by an authorized 
electrician in accordance with local regulations. 

The supply voltage, rated maximum current and cos 

 appear 

from the loose data plate that must be fitted close to the installa-
tion site. 

The required voltage quality for GRUNDFOS MS submersible 
motors, measured at the motor terminals, is +6%/–10% of the 
nominal voltage during continuous operation (including variation 
in the supply voltage and losses in cables). 

The required voltage quality for GRUNDFOS MMS submersible 
motors, measured at the motor terminals, is +5%/–5% of the 
nominal voltage during continuous operation (including variation 
in the supply voltage and losses in cables). 

Furthermore, it must be checked that there is voltage symmetry in 
the electricity supply lines, i.e. same difference of voltage 
between the individual phases, see also section 9. Checking of 
motor and cable
, point
 2

.

In order that the GRUNDFOS MS motors with a built-in and oper-
ational temperature transmitter can meet the EC EMC Directive 
(2004/108/EC), a 0.47 

F capacitor (in accordance with IEC 384-

14) must always be connected over the two phases to which the 
temperature transmitter is connected, see fig. 6.

TM

00 135

5 509

2

Motor type

Power output

50 Hz

Power output

60 Hz

[kW]

[kW]

MS 6000

All sizes

All sizes

MMS 6000

3.7 to 18.5

3.7 to 18.5

MMS 8000

22.0 to 55.0

22.0 to 55.0

MMS 10000

75.0 to 110.0

75.0 to 110.0

MMS 12000

147.0 to 190.0

Allowed

Not allowed

Motor

Installation

Flow past 
the motor 

Vertical Horizontal

GRUNDFOS 

MS and MMS

Free 

convection

0 m/s 

20°C 

(~68°F)

Flow sleeve 

recommended

GRUNDFOS 

MS

0.15 m/s 

40°C 

(~105°F)

40°C

(~105°F)

GRUNDFOS 

MMS

0.15 m/s

25°C 

(~77°F)

25°C

(~77°F)

Before starting work on the pump, make sure that the 
electricity supply has been switched off and that it 
cannot be accidentally switched on.

The pump must be earthed. 

The pump must be connected to an external mains 
switch.

Summary of Contents for SP-G

Page 1: ...SP G GRUNDFOS INSTRUCTIONS Installation and operating instructions ...

Page 2: ... 60335 1 2002 e EN 60335 2 41 2003 excepto nos pontos 25 1 e 25 8 Bomba com ponta de veio livre A Grundfos declara sob sua única responsabilidade que os produtos SP G aos quais diz respeito esta declaração estão em conformidade com as seguintes Directivas do Conselho sobre a aproximação das legislações dos Estados Membros da CE Directiva Máquinas 2006 42 CE Norma utilizada EN 809 2009 Antes de col...

Page 3: ...24 Istruzioni di installazione e funzionamento 34 Instrucciones de instalación y funcionamiento 43 Instruções de instalação e funcionamento 52 Οδηγίες εγκατάστασης και λειτουργίας 62 Installatie en bedieningsinstructies 72 Monterings och driftsinstruktion 82 Asennus ja käyttöohjeet 91 Monterings og driftsinstruktion 100 ...

Page 4: ...e a month If a motor has been stored for more than one year before installa tion the rotating parts of the motor must be dismantled and checked before use The pump should not be exposed to direct sunlight If the pump has been unpacked it should be stored horizontally adequately supported or vertically to prevent misalignment of the pump Make sure that the pump cannot roll or fall over During stora...

Page 5: ...ith the filling syringe fig 3 until the liquid runs back out of the filling hole 4 Replace the screw in the filling hole and tighten securely before changing the position of the pump Torque 3 0 Nm The submersible pump is now ready for installation Fig 3 3 1 3 Refilling GRUNDFOS submersible motors MMS 6000 MMS 8000 MMS 10000 and MMS 12000 To refill the motor proceed as follows 1 Position the submer...

Page 6: ...tor makes See motor specifications 4 Electrical connection 4 1 General The electrical connection should be carried out by an authorized electrician in accordance with local regulations The supply voltage rated maximum current and cos appear from the loose data plate that must be fitted close to the installa tion site The required voltage quality for GRUNDFOS MS submersible motors measured at the m...

Page 7: ...ter must be protected by means of a motor starter with thermal relay or a CU 3 and contactor s GRUNDFOS MMS motors have no built in temperature transmit ter A Pt100 sensor is available as an accessory Motors with a Pt100 sensor must be protected by means of a motor starter with thermal relay or a CU 3 and contactor s Motors without a Pt100 sensor must be protected by means of a motor starter with ...

Page 8: ... Specific resistance 0 02 mm m q Cross section of submersible drop cable mm sin 0 436 Xl Inductive resistance 0 078 x 10 3 m 4 5 Connection of motor Three phase submersible motors must be protected see section 4 2 Motor protection For electrical connection by means of the CU 3 see the separate installation and operating instructions for this unit When a conventional motor starter is being used the...

Page 9: ...ightened diagonally to the torques stated in the following table Note Make sure that the pump chambers are aligned when assembly has been completed 5 2 Fitting of submersible drop cable Before fitting the submersible drop cable to the motor make sure that the cable socket is clean and dry To facilitate the fitting of the cable lubricate the rubber parts of the cable plug with non conducting silico...

Page 10: ...osed off to approx 1 3 of its maximum volume of water Check the direction of rotation as described in section 4 5 1 Checking of direction of rotation If there are impurities in the water the valve should be opened gradually as the water becomes clearer The pump should not be stopped until the water is completely clean as otherwise the pump parts and the non return valve may choke up As the valve i...

Page 11: ...d at a GRUNDFOS service centre If GRUNDFOS is requested to service the pump GRUNDFOS must be contacted with details about the pumped liquid etc before the pump is returned for service Otherwise GRUNDFOS can refuse to accept the pump for service Possible costs of returning the pump are paid by the customer If a pump has been used for a liquid which is injurious to health or toxic the pump will be c...

Page 12: ... rotation c The valves in the discharge pipe are partly closed blocked Check and clean replace the valves if necessary d The discharge pipe is partly choked by impurities ochre Clean replace the discharge pipe e The non return valve of the pump is partly blocked Pull out the pump and check replace the valve f The pump and the riser pipe are partly choked by impurities ochre Pull out the pump Check...

Page 13: ... the full load current there are the following possible faults The contacts of the motor starter burnt Replace the con tacts Poor connection in leads possibly in the cable joint See item 3 Too high or too low supply voltage See item 1 The motor windings are short circuited or partly disjointed See item 3 Damaged pump is causing the motor to be overloaded Pull out the pump for overhaul The resistan...

Page 14: ... Bride Flangia Brida Flange Φλάντζα Flens Fläns Laippa Flange Motor Motor Moteur Motore Motor Motor Κινητήρας Motor Motor Moottori Motor Direct On Line Starting Direktanlauf Démarrage direct Avviamento diretto Arranque directo Arranque directo Απευθείας Εκκίνηση Directe aanloop Direktstart Suorakäynnistys Direkte start Star Delta Starting Stern Dreieck Anlauf Démarrage étoile triangle Avviamento Y...

Page 15: ... 3 x 400 V I 40 A L 140 m U 2 Lx L U 140 2 70 m q 25 mm 2 TM00 1346 5092 I 40 A U 2 U 3 x 400 V L 140 m Example U 3 x 380 V I 10 A L 120 m U 2 Lx L U 120 2 60 m q 6 mm 2 TM00 1345 5092 I 10 A U 2 U 3 x 380 V L 120 m ...

Page 16: ...3 x 220 V I 5 A L 105 m U 3 Lx L U 105 3 35 m q 2 5 mm 2 TM00 1348 5092 I 5 A U 3 U 3 x 220 V L 105 m Example U 3 x 415 V I 100 A L 150 m U 3 Lx L U 150 3 50 m q 50 mm 2 TM00 1347 5092 I 100 A U 3 U 3 x 415 V L 150 m ...

Page 17: ...112 ...

Page 18: ...113 ...

Page 19: ...114 ...

Page 20: ...ps Korea Ltd 6th Floor Aju Building 679 5 Yeoksam dong Kangnam ku 135 916 Seoul Korea Phone 82 2 5317 600 Telefax 82 2 5633 725 Latvia SIA GRUNDFOS Pumps Latvia Deglava biznesa centrs Augusta Deglava ielā 60 LV 1035 Rīga Tālr 371 714 9640 7 149 641 Fakss 371 914 9646 Lithuania GRUNDFOS Pumps UAB Smolensko g 6 LT 03201 Vilnius Tel 370 52 395 430 Fax 370 52 395 431 Malaysia GRUNDFOS Pumps Sdn Bhd 7 ...

Page 21: ...www grundfos com Being responsible is our foundation Thinking ahead makes it possible Innovation is the essence 96432078 0711 Repl 96432078 0506 ECM 1078259 ...

Reviews: