English (GB)
32
The supply cable resistance depends on the cable diameter.
Resistance per running metre of cable: 1.5 mm
2
= 0.012
Ω
.
Resistance per running metre of cable: 2.5 mm
2
= 0.007
Ω
.
13. Disposal
This product or parts of it must be disposed of in an
environmentally sound way:
1. Use the public or private waste collection service.
2. If this is not possible, contact the nearest Grundfos company
or service workshop.
Subject to alterations.
4-pole motor
Cable connection
Power P
2
[kW]
Power P
1
[kW]
Voltage
[V]
Starting method
Thermal protection
Cable cross section
[mm
2
]
Conductors /
plug pins
1.1
1.5
3 x 380-415
DOL
Thermal switch
1.5
7/7
1.1
1.5
3 x 400-415
DOL
Thermal switch
1.5
7/7
1.3
1.8
3 x 380-415
DOL
Thermal switch
1.5
7/7
1.3
1.8
3 x 400-415
DOL
Thermal switch
1.5
7/7
1.5
2.1
3 x 380-415
DOL
Thermal switch
1.5
7/7
1.5
2.1
3 x 400-415
DOL
Thermal switch
1.5
7/7
2.2
2.9
3 x 380-415
DOL
Thermal switch
1.5
7/7
2.2
2.9
3 x 380-415
Y/D
Thermal switch
1.5
10/10
2.2
2.9
3 x 400-415
DOL
Thermal switch
1.5
7/7
3
3.7
3 x 380-415
DOL
Thermal switch
1.5
7/7
3
3.7
3 x 380-415
Y/D
Thermal switch
1.5
10/10
3
3.7
3 x 400-415
DOL
Thermal switch
2.5
7/7
4
4.9
3 x 380-415
Y/D
Thermal switch
2.5
10/10
4
4.9
3 x 400-415
DOL
Thermistor
2.5
7/10
5.5
6.5
3 x 380-415
Y/D
Thermal switch
2.5
10/10
5.5
6.5
3 x 400-415
DOL
Thermistor
2.5
7/10
7.5
9.0
3 x 380-415
Y/D
Thermal switch
2.5
10/10
7.5
9.0
3 x 400-415
DOL
Thermistor
2.5
7/10
Summary of Contents for SL1.100.100.40.4
Page 39: ...Appendix 39 15 Exploded drawings SLV TM04 2777 2605...
Page 40: ...Appendix 40 SL1 TM04 2778 0904...
Page 41: ...41...